DXD-M/K 75÷600

Ducted Blower Split Systems

SOLO_FREDDO.png CALDO_FREDDO_MIDY.png COMPRESSORE_SCROLL111.png R410A1.png

The ducted blower Split Systems of DXD-M/K series are the ideal solution for keeping the best comfort level in large-sized spaces as offices, shops, hotels or education facilities.
The range comprises 12 models from 75.000 BTU/h to 600.000 BTU/h and the systems are composed of one indoor unit connected to up to four outdoor units, depending on the cooling capacity required.
The systems operate with R410A refrigerant and feature Scroll compressor.
The units are designed for installation both in service rooms or built-in; the air ducts, totally hidden on the ceiling or on walls, provide the perfect comfort without compromising on the building architecture and design. Models over 125.000 BTU/h feature both horizontal and vertical air outlet, which can be chosen directly onsite, to allow the highest flexibility in installation.
The ducts ensure an even distribution of conditioned air to every corner of the room. Even multiple areas can be conditioned simultaneously just with one indoor unit.
The range is characterized by low-noise operation of both internal units and external units, thanks to the high level acoustic insulation.

Versionen

  • DXD-M/K - Cooling only (INU)
  • DXD-M/K - Cooling only (OTU)
  • DXD-M/K/WP - Reversible Heat Pump (INU)
  • DXD-M/K/WP - Reversible Heat Pump (OTU)

Merkmale

  • Indoor and Outdoor units are made of galvanized steel sheet with electrostatic powder paint. Indoor units are complete with polyethylene for thermal and acoustical purpose.
  • Scroll compressors with oil sight glass, with internal overheat protection and crankcase heater.
  • Indoor units are provided with radial fans, directly coupled with single-phase 3-speed electric motor (to build model's sizes 75 – 100) or to 3-phase motors by V belt and variable pulley (to build model's sizes 125-600). Outdoor units are provided axial fans directly coupled to electric motor.
  • Indoor units to build models' sizes 75 - 150 come with standard horizontal air discharge; indoor units to build models' sizes 125 - 150 are convertible to vertical air discharge on site. Indoor units to build models' sizes 200 - 600 come with standard vertical air discharge and they are convertible to horizontal air discharge on site.
  • Indoor and Outdoor units are provided with copper tube and aluminum finned coils precharged with nitrogen.
  • All Indoor units are provided with return air plenum and standard cleanable filter.
  • Microprocessor for the automatic control of the unit allowing continuous display of the operational status, control the set and real air temperature and, in case of partial or total unit stop, indication of security device that intervened through a wired wall pad as standard.
  • Units matching with two or more outdoor units are provided with a sequential controller allowing part loading of the system capacity.
  • Wired wall pad included on indoor unit.
75100125150200250300350400450500600
ModellInneneinheit1 x 75 INU1 x 100 INU1 x 125 INU1 x 150 INU1 x 200 INU1 x 250 INU1 x 300 INU1 x 350 INU1 x 400 INU1 x 450 INU1 x 500 INU1 x 600 INU
Außeneinheit1 x 75 OTU1 x 100 OTU1 x 125 OTU1 x 150 OTU2 x 100 OTU2 x 125 OTU2 x 150 OTU2 x 125 OTU 1 x 100 OTU4 x 100 OTU3 x 150 OTU4 x 125 OTU4 x 150 OTU
KühlungKühlleistung (1)BTU/h75000100000125000150000200000250000300000350000400000450000500000600000
Kühlleistung (1)kW22,029,336,643,958,673,287,9103117132147176
Leistungsaufnahme (1)kW8,911,414,116,723,328,935,943,645,752,962,967,6
HeizungHeizleistung (2)BTU/h78200104000129700155800207600259500311400363300415200467100519000622800
Heizleistung (2)kW22,930,538,045,660,876,091,2106122137152182
Leistungsaufnahme (2)kW7,409,6012,8014,6519,0023,5029,3035,6037,3043,1051,2055,10
InneneinheitMax Luftmengem³/s1,21,31,92,13,03,74,25,05,76,46,98,3
NutzförderhöhePa150150150150150200200200200250250300
Flüssigkeitsanschlussinch5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"
Gasanschlussinch1-1/8"1-1/8"1-3/8"1-3/8"1-1/8"1-3/8"1-3/8"1-3/8" . 1-1/8"1-1/8"1-3/8"1-3/8"1-3/8"
Kondensabflussinch1"1"1"1"1"1"1"1"1"1"1"1"
Max Schalldruck (3)dB(A)565758596062656566676868
AußeneinheitVerdichter111111111111
VerdichterTipoScrollScrollScrollScrollScrollScrollScrollScrollScrollScrollScrollScroll
Flüssigkeitsanschlussinch5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"5/8"
Gasanschlussinch1-1/8"1-1/8"1-3/8"1-3/8"1-1/8"1-3/8"1-3/8"1-3/8" . 1-1/8"1-1/8"1-3/8"1-3/8"1-3/8"
Schalldruck (4)dB(A)575758585757585757585758
Max Länge AnschlüsseMax Abstand OTU-INU (5)m505050505050505050505050
Max Höhe OTU-INU (5)m303030303030303030303030
Elektrische MerkmaleVersorgungsspannung InneneinheitV/Ph/Hz230/1/50230/1/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50
Versorgungsspannung AußeneinheitV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. BetriebsstromA202626324354728184102116130
Max. AnlaufstromA102128146180145173217201187250237279
GewichteTransportgewicht Inneneinheit (6)kg127150215217235368378503556570850920
Transportgewicht Außeneinheit (6)kg185190197230190197230197 / 190190230197230
Betriebsgewicht Außeneinheit (6)kg175180187220180187220187/180180220187220
Betriebsgewicht Inneneinheit (6)kg122145210212225358368493546560840910

Dimensions

75100125150200250300350400450500600
LINTERNE EINHEITmm158018801575157519051905190519052420242024202440
EXTERNE EINHEITmm9659659651130965965113096596511309651130
WINTERNE EINHEITmm7657659859859851240124012401520152015201820
EXTERNE EINHEITmm9759759751110975975111097597511109751110
HINTERNE EINHEITmm4304308708708701165116513851385138513851770
EXTERNE EINHEITmm950950950950950950100095095010009501000

Aufzeichnungen

  • 1 Innenlufttemperatur 27 °C FK/19 °C TK; Aussenlufttemperatur 35 °C FK
  • 2 Innenlufttemperatur 20 °C FK; Aussenlufttemperatur 7 °C TK /6 °C FK
  • 3 Schalldruck im Abstand von 1 m zur Einheit mit einer Nachhallzeit von 0,5 s.
  • 4 Durchschnittlicher Schalldruckpegel im Freifeld im Abstand von 1 m zur Einheit, gemäß ISO 3744.
  • 5 Erreichbare Höchstlänge mit entsprechendem Leitungsdurchmesser und Siphonen.
  • 6 Einheit nur Kühlung