_clint_hydroplus.png

CWW-M/K 181-P÷522-P

Watercooled liquid Chillers and Heat Pumps with Scroll compressors and plate exchangers

SOLO_FREDDO.png caldo_e_freddo1.png COMPRESSORE_SCROLL111.png SCAMBIATORE_PIASTRE11.png R410A1.png

The CWW-M/K 181-P÷522-P HYDROPLUS liquid Chillers and Heat Pumps, with R410A refrigerant, are designed for medium-sized domestic or industrial systems which require medium-high power, space-saving units and quiet operation. This range is ideal for indoor installation and, equipped with a self-contained structure, it reduces the overall dimensions to a minimum while at the same time making installation and maintenance operations easier.
Equipped with prepainted plate structure, Scroll compressors and plate type exchangers, these units have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency, even in the version with tank and pump.
A wide series of accessories, factory-assembled or supplied separately, such as the desuperheater or the total heat recovery, rounds off the variety of equipment in this product range.

Versionen

  • CWW-M/K - Cooling only
  • CWW-M/K/WP - Reversible Heat Pump

Power range

  • 58,0-176 kW
  • 16,0-50,0 Ton

Merkmale

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side.
  • Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side, completed with water differential pressure switch.
  • R410A refrigerant.
  • Electrical board includes: main switch with door safety interlock, protection modules and overload protection for compressors.
  • Microprocessor control and regulation system.

Im Werk montiertes Zubehör

  • SL Schalldämmung der Einheit
  • BT Ausführung für Betrieb mit niedriger Wassertemperatur
  • DS Enthitzer
  • RT Vollständige Wärmerückgewinnung
  • IS Modbus RTU-Protokoll, serielle Schnittstelle RS485

Lose mitgeliefertes Zubehör

  • MN Hoch- und Niederdruckmanometer
  • CR Fernbedienung
  • SPU Pufferspeicher und einzelne Umwälzpumpe
  • SPD Pufferspeicher und doppelte Umwälzpumpe
  • PV2 Elektronisches 2-Wege-Druckregelventil
  • PV3 Elektronisches 3-Wege-Druckregelventil
  • AG Gummi-Schwingungsdämpfer
  • AG1 Rubber shock absorbers for SPU and SPD modules
181-P241-P301-P392-P522-P
KühlungKühlleistung (1)kW57,573,994,5137176
Leistungsaufnahme (1)kW13,216,921,931,941,3
Kühlung (EN14511)Kühlleistung (1)kW57,173,494,0136175
Leistungsaufnahme (1)kW14,017,923,133,543,5
EER (1)4,084,084,074,074,03
HeizungHeizleistung (2)kW71,392,4116168218
Leistungsaufnahme (2)kW16,821,327,640,651,9
Heizung (EN14511)Heizleistung (2)kW71,993,2117169219
Leistungsaufnahme (2)kW17,722,528,842,354,2
COP (2)4,064,144,064,004,05
VerdichterAnzahl11122
Kältekreisläufe11111
Leistungsstufen11122
VerdampferWassermengel/s2,753,534,526,558,41
DruckverlustekPa4352465156
WasseranschlüsseDN3232656565
VerflüssigerWassermengel/s3,384,345,568,0710,38
DruckverlustekPa5259485460
WasseranschlüsseDN3232656565
Elektrische MerkmaleVersorgungsspannungV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50
Max. BetriebsstromA39485995119
Max. AnlaufstromA215260320308379
Einheit mit Speicher und PumpeNutzförderhöhe der PumpekPa125100120125120
Wasserinhalt Speicherl300300300300300
Wasseranschlüsse"G2 ½"2 ½"2 ½"2 ½"2 ½"
SchalldruckVersion STD (3)dB(A)5959606062
Mit Zubehör SL (3)dB(A)5656575759
GewichteTransportgewicht (4)kg372391456609725
Betriebsgewicht (4)kg380400470620750

Dimensions

181-P241-P301-P392-P522-P
LEINHEITmm12001200120016001600
EINHEIT + SPU/SPDmm23102310231027102710
WEINHEITmm680680680680680
EINHEIT + SPU/SPDmm680680680680680
HEINHEITmm15201520152015201520
EINHEIT + SPU/SPDmm15201520152015201520

Aufzeichnungen

  • 1 Kaltwasser von 12 bis 7 °C, Wassertemperatur am Verflüssiger von 30 bis 35 °C.
  • 2 Warmwasser von 40 bis 45 °C, Wassertemperatur am Verdampfer von 15 bis 10 °C.
  • 3 Durchschnittlicher Schalldruckpegel im Freifeld im Abstand von 1 m zur Einheit, gemäß ISO 3744.
  • 4 Einheit ohne Speicher und Pumpe.
  • N.B. (1) Die Gewichte der Version WP sind in den technischen Unterlagen aufgeführt.