CHV/P/HE/MC 152-P÷756-P
High efficiency air cooled liquid chillers with EC Inverter axial fans, scroll compressors and plate exchanger.
ECO V-THERM is the new range of air cooled liquid Chillers designed for high performance while respecting the environment.
The high efficiency liquid Chillers of the CHV/P/HE/MC 152-P÷756-P series, with R290 refrigerant, are designed to satisfy the needs of medium-sized service sector or industrial ambients.
They are used, combined with Fan Coil units, for the air conditioning of the rooms.
Using the natural refrigerant R290, with an extremely low GWP, they meet current and future European environmental regulations, combining efficiency and sustainability.
Microchannel condensing coils minimise the amount of refrigerant required in the units.
The units are compliant to the ErP Regulation.
Versions
- CHV/P/HE/MC - High efficiency cooling only with MICROCHANNEL coils
Power range
- 49.0-226 kW
- 14.0-64.0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Compressor box housed on the side of the unit opposite the electrical board ad equipped with an ATEX-certified extraction fan installed at the bottom of the compartment.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- EC Inverter axial fans directly coupled to an Inverter three-phase electric motor with external rotor.
- Condenser made up of aluminium Microchannel coils positioned in a V-shaped geometry.
- Evaporator AISI 316 stainless steel braze welded plates type with one (mod. 152-P÷383-P) or two (mod. 404-P÷756-P) independent circuits on the refrigerant side and one on the water side.
- Cooling circuit shut-off valve on liquid line.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R290 refrigerant.
- Electrical board includes: main switch with door safety interlock, automatic cirtcuit brakers, thermal protection relays for compressors and thermocontacts for fans.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- BT Low water temperature kit
- BTA Low ambient air temperature kit
- DS Desuperheater
- TXB Coil with epoxy treatment
- SI Inertial tank
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FX Antifreeze heater for evaporator and pipes
- FQ Antifreeze heater on evaporator, tank and pipes
- FZ Antifreeze heater for evaporator, single pump and pipes
- FH Antifreeze heater for evaporator, double pump and pipes
- FU Antifreeze heater for evaporator, tank, single pump and pipes
- FD Antifreeze heater for evaporator, tank, double pump and pipes
- SS Soft start
- WM Web Monitoring - Wireless remote monitoring (4G)
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- ISS SNMP protocol, Ethernet port
- MTS Master/Slave Network Management
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- LDS Leak detection sensor R290
- RP Coils protection metallic guards
Loose accessories
- CR Remote control panel
- FL Flow switch
- AG Rubber shock absorbers
- AM Spring shock absorbers
Technical data
| 152-P | 182-P | 202-P | 252-P | 303-P | 383-P | 404-P | 504-P | 606-P | 756-P | |||
| Cooling | Cooling capacity (1) | kW | 49,4 | 56,6 | 69,1 | 76,9 | 95,0 | 113 | 143 | 154 | 189 | 226 |
| Absorbed power (1) | kW | 15,4 | 17,5 | 20,3 | 21,5 | 28,1 | 34,5 | 39,2 | 43,0 | 55,8 | 68,3 | |
| EER (1) | 3,21 | 3,23 | 3,40 | 3,58 | 3,38 | 3,28 | 3,65 | 3,58 | 3,39 | 3,31 | ||
| Cooling (EN14511) | Cooling capacity (1) | kW | 49,3 | 56,5 | 69,0 | 76,8 | 94,9 | 113 | 143 | 154 | 189 | 226 |
| EER (1) | 3,17 | 3,21 | 3,37 | 3,54 | 3,36 | 3,26 | 3,61 | 3,54 | 3,35 | 3,28 | ||
| SEER (2) | 4,55 | 4,56 | 4,60 | 4,64 | 4,64 | 4,63 | 4,80 | 4,75 | 4,76 | 4,70 | ||
| Energy Efficiency (2) | % | 179 | 179 | 181 | 183 | 183 | 182 | 189 | 187 | 187 | 185 | |
| Compressor | Quantity | N° | 2 | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 6 | 6 |
| Refrigerant circuits | N° | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | |
| Capacity steps | N° | 2 | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 6 | 6 | |
| Evaporator | Water flow | l/s | 2,36 | 2,70 | 3,29 | 3,66 | 4,53 | 5,39 | 6,82 | 7,34 | 9,01 | 10,80 |
| Pressure drops | kPa | 22,5 | 15,6 | 18,2 | 19,9 | 11,9 | 12,5 | 22,3 | 24,9 | 22,8 | 20,6 | |
| Water connections | DN | 2" | 2" | 2" | 2" | 2" | 2" | 2"1/2 | 2"1/2 | 3" | 3" | |
| Electrical characteristics | Power supply | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
| Max. running current | A | 51,7 | 55,5 | 63,2 | 74,4 | 90,9 | 108 | 126 | 149 | 182 | 215 | |
| Max. starting current | A | 175 | 175 | 183 | 238 | 210 | 271 | 246 | 313 | 301 | 379 | |
| Unit with pump | Pump available static pressure | kPa | 161 | 162 | 149 | 140 | 129 | 108 | 172 | 164 | 147 | 127 |
| Water connections | DN | 2" | 2" | 2" | 2" | 2" | 2" | 2"1/2 | 2"1/2 | 3" | 3" | |
| Sound power | STD version (3) | dB(A) | 82 | 82 | 84 | 84 | 85 | 85 | 87 | 87 | 88 | 88 |
| With SL accessory (3) | dB(A) | 80 | 80 | 82 | 82 | 83 | 83 | 85 | 85 | 86 | 86 | |
| Weights | Transport weight | kg | 816 | 825 | 1074 | 1083 | 1162 | 1171 | 1906 | 1914 | 2079 | 2112 |
| Operating weight | kg | 820 | 830 | 1080 | 1090 | 1170 | 1180 | 1920 | 1930 | 2100 | 2140 | |
Dimensions
| 152-P | 182-P | 202-P | 252-P | 303-P | 383-P | 404-P | 504-P | 606-P | 756-P | |||
| L | STD | mm | 1600 | 1600 | 2600 | 2600 | 2600 | 2600 | 5000 | 5000 | 5000 | 5000 |
| W | STD | mm | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 |
| H | STD | mm | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 | 2260 |
Notes
- 1 Chilled water from 12 to 7 °C, ambient air temperature 35 °C.
- 2 Seasonal energy efficiency of cooling at low temperature. According to EU Regulation n. 2016/2281.
- 3 Sound power level according to Standard ISO 3744 and Eurovent 8/1.