CHA/IK/TR/A 18÷35

A CLASS energy efficiency aircooled reversible Heat Pumps with EC Inverter axial fans, Inverter Rotary compressor, plate exchanger and hydronic kit

caldo_e_freddo1.png _icon_inverter_Rotary_compressor_14.png icon_EC_Inverter_14_sin.png SCAMBIATORE_PIASTRE11.png DOCCIA_CATALOGONE.png _icon_A_CLASS_2018_heating.png R410A1.png

The reversible Heat Pumps CHA/IK/TR/A 18÷35, in A CLASS energy efficiency, are designed for small domestic or service sector environments. Equipped with R410A refrigerant, Inverter Rotary compressor with DC BRUSHLESS motor and EC INVERTER axial fans, they are extremely functional and reliable units. The Inverter device controls and continuously modulates the compressor speed, keeping the temperature of the water delivered to the system stable and constant and adapting it perfectly to the thermal load of the places where terminal units it feeds are installed. This obtains high energy efficiencies and SCOP values higher than conventional units, and a reduction of compressor starting peak currents, thus considerably reducing the risk of malfunctioning or breakages. The EC Inverter axial fans vary their speed according to the required thermal load, with consequent benefits in terms of energy efficiency and silent operation.
The units are designed for hot water production up to 55°C.
The units are compliant to the ErP Regulation.

Versions

  • CHA/IK/TR/A - Reversible Heat Pump

Power range

  • 5.2-8.2 kW
  • 1.5-2.3 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • DC INVERTER Rotary compressor, with DC BRUSHLESS motor, complete with overload protection.
  • EC INVERTER axial fans with low ventilation and special wing profile, directly coupled to external rotor motors.
  • Condenser with copper tube and aluminium finned coil, complete with condensate drain pan and protection guards.
  • Evaporator plate-type AISI 316 stainless steel, equipped with antifreeze heater.
  • Electronic expansion valve.
  • R410A refrigerant.
  • Electrical board includes: main switch with door lock device, fuses, compressor and pump remote control switch.
  • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device also allows the cooling functioning of the unit by external temperature till -20 °C.
  • Functioning in heating mode with outside air temperature down to -20 °C.
  • Water circuit includes: circulator with high efficiency DC BRUSHLESS motor, flow switch, safety valve, gauge and expansion vessel.
  • Microprocessor control and regulation system.
  • Advanced functions: remote set-point with 0-10V signal, remote set-point with 4-20mA signal, remote signal for second set-point activation, demand limit from digital input, management of hybrid systems, management of domestic hot water production.
  • Communication with Modbus RTU protocol through RS485 serial interface.

Loose accessories

  • CD Room thermostat with unit visualization
  • CDT Touch screen room thermostat with unit visualization
  • AG Rubber shock absorbers
182535
HeatingHeating capacity (1)kW5,186,058,16
Absorbed power (1)kW1,561,952,56
COP (1)3,323,113,19
Heating capacity (2)kW6,107,369,82
Absorbed power (2)kW1,471,972,52
COP (2)4,153,743,90
Heating (EN14511)Heating capacity (1)kW5,145,988,03
Absorbed power (1)kW1,481,872,45
COP (1)3,483,203,28
Heating capacity (2)kW6,057,239,71
Absorbed power (2)kW1,391,852,42
COP (2)4,353,904,02
SCOP (3)4,504,343,96
Energy Efficiency (3)%177171155
Energy Class (4)A+++A++A++
SCOP (5)3,233,132,93
Energy Efficiency (5)%126122114
Energy Class (6)A++A+A+
CoolingCooling capacity (7)kW4,725,468,34
Absorbed power (7)kW1,732,123,05
EER (7)2,732,582,73
Cooling capacity (8)kW4,905,968,98
Absorbed power (8)kW1,341,682,40
EER (8)3,663,553,74
Cooling (EN14511)Cooling capacity (7)kW4,765,588,42
Absorbed power (7)kW1,662,042,92
EER (7)2,862,742,88
Cooling capacity (8)kW5,006,039,10
Absorbed power (8)kW1,261,582,27
EER (8)3,963,814,01
SEER (9)5,594,825,61
Energy Efficiency (9)%221190221
Electrical characteristicsPower supplyV/Ph/Hz230/1/50230/1/50230/1/50
Max. running currentA141920
Max. starting currentA71010
CompressorQuantity111
Water circuit.Water flowl/s0,290,350,46
Pump available static pressurekPa676053
Water connections"G1"1"1"
Sound pressure  (10)dB(A)505555
WeightsTransport weightkg7879103
Operating weightkg707194

Dimensions

182535
LSTDmm105010501160
WSTDmm290290330
HSTDmm685685890

Notes

  • 1 Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b.
  • 2 Heated water from 30 to 35 °C, ambient air temperature 7 °C d.b./6 °C w.b.
  • 3 Seasonal energy efficiency of heating at low temperature with average climatic conditions. According to EU Regulation n. 813/2013.
  • 4 Seasonal energy efficiency class of heating at low temperature with average climatic conditions. According to EU Regulation n. 811/2013.
  • 5 Seasonal energy efficiency of heating at medium temperature with average climatic conditions. According to EU Regulation n. 813/2013.
  • 6 Seasonal energy efficiency class of heating at medium temperature with average climatic conditions. According to EU Regulation n. 811/2013.
  • 7 Chilled water from 12 to 7 °C, ambient air temperature 35 °C.
  • 8 Chilled water from 23 to 18 °C, ambient air temperature 35 °C.
  • 9 Seasonal energy efficiency of cooling at low temperature. According to EU Regulation n. 2016/2281.
  • 10 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.