CHA-M/K 181-P÷522-P
Aircooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger







The liquid Chillers and Heat Pumps of CHA-M/K 181-P÷522-P HYDROPLUS series, with R410A refrigerant, are designed for medium-sized service sector or industrial ambients.
They are used, combined with Fan Coil units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS485 serial interface.
Equipped with axial fans, Scroll compressors and plate exchanger, these units can be completed by a hydraulic circuit with tank, with pump, with tank and pump or with AQUALOGIK technology.
The AQUALOGIK smart control system optimises the water set point and modulates the power supply voltage of the pump and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs.
A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.
Versions
- CHA-M/K - Cooling only
- CHA-M/K/WP - Reversible Heat Pump
- CHA-M/K/ST - Cooling only with AQUALOGIK technology
- CHA-M/SZ/K/WP/ST - Reversible Heat Pump with AQUALOGIK technology
Power range
- 54.0-157 kW
- 15.0-45.0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coil.
- Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side, completed with water differential pressure switch. On the heat pump it is always installed an antifreeze heater.
- R410A refrigerant.
- Electrical board includes: main switch with door safety interlock, protection modules, overload protection for compressors and thermocontacts for fans.
- On ST versions water circuit includes INVERTER circulating pump, safety valve and expansion vessel.
- On ST versions Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to –20 °C in cooling mode. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation, an high/low pressure transducer on cooling circuit and an electrical heater on electrical board.
- Microprocessor control and regulation system (with AQUALOGIK technology on ST versions).
Accessories
Factory fitted accessories
- SL Unit silencement
- CT Condensing control down to 0 °C
- BT Low water temperature kit
- DS Desuperheater
- RT Total heat recovery
- TX Coil with pre-coated fins
- SI Inertial tank
- PS Single circulating pump
- PD Double circulating pump
- IS Modbus RTU protocol, RS485 serial interface
Loose accessories
- MN High and low pressure gauges
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
Technical data
181-P | 241-P | 301-P | 392-P | 522-P | |||
Cooling | Cooling capacity (1) | kW | 53,7 | 66,0 | 88,4 | 124 | 157 |
Absorbed power (1) | kW | 18,0 | 22,6 | 29,4 | 45,0 | 60,0 | |
EER (1) | 2,98 | 2,92 | 3,01 | 2,76 | 2,62 | ||
Cooling (EN14511) | Cooling capacity (1) | kW | 53,3 | 65,5 | 87,9 | 123 | 156 |
Absorbed power (1) | kW | 18,4 | 23,1 | 29,9 | 45,7 | 60,7 | |
EER (1) | 2,90 | 2,84 | 2,94 | 2,69 | 2,57 | ||
Heating | Heating capacity (2) | kW | 59,9 | 74,8 | 96,1 | 137 | 172 |
Absorbed power (2) | kW | 19,3 | 24,3 | 30,6 | 45,5 | 57,8 | |
COP (2) | 3,10 | 3,08 | 3,14 | 3,01 | 2,98 | ||
Heating (EN14511) | Heating capacity (2) | kW | 60,4 | 75,4 | 96,6 | 138 | 173 |
Absorbed power (2) | kW | 20,0 | 25,1 | 31,3 | 47,0 | 59,1 | |
COP (2) | 3,02 | 3,00 | 3,09 | 2,94 | 2,93 | ||
Compressor | Quantity | n° | 1 | 1 | 1 | 2 | 2 |
Refrigerant circuits | n° | 1 | 1 | 1 | 1 | 1 | |
Capacity steps | n° | 1 | 1 | 1 | 2 | 2 | |
Evaporator | Water flow | l/s | 2,57 | 3,15 | 4,22 | 5,92 | 7,50 |
Pressure drops | kPa | 64 | 59 | 46 | 62 | 49 | |
Water connections | "G | 1 ½" | 1 ½" | 2 ½" | 2 ½" | 2 ½" | |
Electrical characteristics | Power supply | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
Max. running current | A | 43 | 52 | 67 | 103 | 127 | |
Max. starting current | A | 219 | 264 | 328 | 316 | 387 | |
Electrical characteristics (ST versions) | Power supply | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
Max. running current | A | 45 | 54 | 70 | 108 | 132 | |
Max. starting current | A | 221 | 266 | 331 | 321 | 392 | |
Unit with tank and pump | Pump available static pressure | kPa | 100 | 95 | 130 | 110 | 100 |
Tank water volume | l | 400 | 400 | 400 | 400 | 400 | |
Expansion vessel | l | 12 | 12 | 12 | 12 | 12 | |
Water connections | "G | 2 ½" | 2 ½" | 2 ½" | 2 ½" | 2 ½" | |
Unit ST versions | Water flow | l/s | 2,57 | 3,15 | 4,22 | 5,92 | 7,50 |
Pump available static pressure | kPa | 100 | 95 | 130 | 110 | 95 | |
Expansion vessel | l | 12 | 12 | 12 | 12 | 12 | |
Water connections | "G | 2 ½" | 2 ½" | 2 ½" | 2 ½" | 2 ½" | |
Sound power | With SL accessory (3) | dB(A) | MANCA | MANCA | MANCA | MANCA | MANCA |
Sound pressure | With SL accessory (4) | dB(A) | 57 | 57 | 59 | 61 | 61 |
Weights | Transport weight (5) | kg | 573 | 612 | 722 | 871 | 987 |
Operating weight (5) | kg | 580 | 620 | 740 | 890 | 1010 | |
Weights (ST versions) | Transport weight | kg | 588 | 627 | 737 | 891 | 1007 |
Operating weight | kg | 595 | 635 | 755 | 910 | 1030 |
Dimensions
181-P | 241-P | 301-P | 392-P | 522-P | |||
L | STD | mm | 2350 | 2350 | 2350 | 2350 | 2350 |
W | STD | mm | 1100 | 1100 | 1100 | 1100 | 1100 |
H | STD | mm | 1920 | 1920 | 1920 | 2220 | 2220 |
Notes
- 1 Chilled water from 12 to 7 °C, ambient air temperature 35 °C.
- 2 Heated water from 40 to 45 °C, ambient air temperature 7 °C d.b./6 °C w.b.
- 3 Sound power level according to Standard ISO 3744 and Eurovent 8/1.
- 4 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
- 5 Unit without tank and pump.
- N.B. (1) Weights of WP versions are specified on technical brochure.
Documents
- Product overview 00_clint_international_product_over_09.2019_w.pdf
- Product guides _clint_international_product_guide_09.2019_w.pdf
- Commercial leaflets 02_clint_international_leaflet_hydroplus_09.2019_w.pdf
- Technical brochures 03_CHA-M_K_181-P-522-P_clbm_61.7.pdf
- Installation, use and maintenance manuals CHA-MK_181P_522P_CLMM_61.7_lRAj8te.pdf