CHA-M/K 181-P÷522-P
Aircooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger







The liquid Chillers and Heat Pumps of CHA-M/K 181-P÷522-P HYDROPLUS series, with R410A refrigerant, are designed for medium-sized service sector or industrial ambients.
They are used, combined with Fan Coil units, for the air conditioning of the rooms or to remove the heat developed during industrial processes. They can be supplied with Modbus RTU protocol through RS485 serial interface.
Equipped with axial fans, Scroll compressors and plate exchanger, these units can be completed by a hydraulic circuit with tank, with pump, with tank and pump or with AQUALOGIK technology.
The AQUALOGIK smart control system optimises the water set point and modulates the power supply voltage of the pump and the fans, thus making the use of the inertial tank superfluous. This obtains high energy efficiency, quiet operation and optimised dimensions and costs.
A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.
Versiones
- CHA-M/K - Cooling only
- CHA-M/K/WP - Reversible Heat Pump
- CHA-M/K/ST - Cooling only with AQUALOGIK technology
- CHA-M/SZ/K/WP/ST - Reversible Heat Pump with AQUALOGIK technology
Power range
- 54,0-157 kW
- 15,0-45,0 Ton
Características
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coil.
- Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side, completed with water differential pressure switch. On the heat pump it is always installed an antifreeze heater.
- R410A refrigerant.
- Electrical board includes: main switch with door safety interlock, protection modules, overload protection for compressors and thermocontacts for fans.
- On ST versions water circuit includes INVERTER circulating pump, safety valve and expansion vessel.
- On ST versions Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to –20 °C in cooling mode. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation, an high/low pressure transducer on cooling circuit and an electrical heater on electrical board.
- Microprocessor control and regulation system (with AQUALOGIK technology on ST versions).
Accesorios
Accesorios montados en fábrica
- SL Silenciamiento unidad
- CT Control de condensación hasta 0 ° C
- BT Dispositivo para funcionamiento a baja temperatura del agua
- DS Desobrecalentador
- RT Recuperador de calor total
- TX Batería con aletas prebarnizadas
- SI Depósito de inercia
- PS Bomba de circulación simple
- PD Bomba de circulación doble
- IS Protocolo Modbus RTU, interfaz serial RS485
Accesorios suministrados por separado
- MN Manómetros de alta y baja presión
- CR Control remoto
- RP Mallas de protección baterías
- AG Antivibratorios de caucho
Technical data
181-P | 241-P | 301-P | 392-P | 522-P | |||
Refrigeración | Potencia frigorífica (1) | kW | 53,7 | 66,0 | 88,4 | 124 | 157 |
Potencia absorbida (1) | kW | 18,0 | 22,6 | 29,4 | 45,0 | 60,0 | |
EER (1) | 2,98 | 2,92 | 3,01 | 2,76 | 2,62 | ||
Refrigeración (EN14511) | Potencia frigorífica (1) | kW | 53,3 | 65,5 | 87,9 | 123 | 156 |
Potencia absorbida (1) | kW | 18,4 | 23,1 | 29,9 | 45,7 | 60,7 | |
EER (1) | 2,90 | 2,84 | 2,94 | 2,69 | 2,57 | ||
Calefacción | Potencia térmica (2) | kW | 59,9 | 74,8 | 96,1 | 137 | 172 |
Potencia absorbida (2) | kW | 19,3 | 24,3 | 30,6 | 45,5 | 57,8 | |
COP (2) | 3,10 | 3,08 | 3,14 | 3,01 | 2,98 | ||
Calefacción (EN14511) | Potencia térmica (2) | kW | 60,4 | 75,4 | 96,6 | 138 | 173 |
Potencia absorbida (2) | kW | 20,0 | 25,1 | 31,3 | 47,0 | 59,1 | |
COP (2) | 3,02 | 3,00 | 3,09 | 2,94 | 2,93 | ||
Compresor | Cantidad | n° | 1 | 1 | 1 | 2 | 2 |
Circuitos frigorifícos | n° | 1 | 1 | 1 | 1 | 1 | |
Etapas de parcialización | n° | 1 | 1 | 1 | 2 | 2 | |
Evaporador | Caudal de agua | l/s | 2,57 | 3,15 | 4,22 | 5,92 | 7,50 |
Pérdidas de carga | kPa | 64 | 59 | 46 | 62 | 49 | |
Conexiones hidráulicas | "G | 1 ½" | 1 ½" | 2 ½" | 2 ½" | 2 ½" | |
Características eléctricas | Alimentación | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
Corriente máx. funcionamiento | A | 43 | 52 | 67 | 103 | 127 | |
Corriente máx. de arranque | A | 219 | 264 | 328 | 316 | 387 | |
Características eléctricas (versiónes ST) | Alimentación | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
Corriente máx. funcionamiento | A | 45 | 54 | 70 | 108 | 132 | |
Corriente máx. de arranque | A | 221 | 266 | 331 | 321 | 392 | |
Unidad con depósito y bomba | Presión estática útil bomba | kPa | 100 | 95 | 130 | 110 | 100 |
Contenido de agua depósito | l | 400 | 400 | 400 | 400 | 400 | |
Vaso de expansión | l | 12 | 12 | 12 | 12 | 12 | |
Conexiones hidráulicas | "G | 2 ½" | 2 ½" | 2 ½" | 2 ½" | 2 ½" | |
Unidad versiónes ST | Caudal de agua | l/s | 2,57 | 3,15 | 4,22 | 5,92 | 7,50 |
Presión estática útil bomba | kPa | 100 | 95 | 130 | 110 | 95 | |
Vaso de expansión | l | 12 | 12 | 12 | 12 | 12 | |
Conexiones hidráulicas | "G | 2 ½" | 2 ½" | 2 ½" | 2 ½" | 2 ½" | |
Potencia sonora | Con accesorio SL (3) | dB(A) | MANCA | MANCA | MANCA | MANCA | MANCA |
Presión sonora | Con accesorio SL (4) | dB(A) | 57 | 57 | 59 | 61 | 61 |
Pesos | Peso de transporte (5) | kg | 573 | 612 | 722 | 871 | 987 |
Peso en funcionamiento (5) | kg | 580 | 620 | 740 | 890 | 1010 | |
Pesos (versiónes ST) | Peso de transporte | kg | 588 | 627 | 737 | 891 | 1007 |
Peso en funcionamiento | kg | 595 | 635 | 755 | 910 | 1030 |
Dimensions
181-P | 241-P | 301-P | 392-P | 522-P | |||
L | STD | mm | 2350 | 2350 | 2350 | 2350 | 2350 |
W | STD | mm | 1100 | 1100 | 1100 | 1100 | 1100 |
H | STD | mm | 1920 | 1920 | 1920 | 2220 | 2220 |
Notas
- 1 Agua refrigerada de 12 a 7 °C, temperatura del aire exterior 35 °C.
- 2 Agua calentada de 40 a 45 °C, temperatura del aire exterior 7 °C b.s./6 °C b.h.
- 3 Nivel de potencia sonora conforme a las normas ISO 3744 y Eurovent 8/1.
- 4 Nivel de presión sonora medida en campo libre a 1 m de la unidad conforme a ISO 3744.
- 5 Unidad sin depósito y bomba.
- N.B. (1) Los pesos de las versiónes WP se indican en el manual técnico.
Documentos
- Gama de productos 00_clint_international_product_over_09.2019_w.pdf
- Guías de productos _clint_international_product_guide_09.2019_w.pdf
- Folletos comerciales 02_clint_international_leaflet_hydroplus_09.2019_w.pdf
- Cuadernos técnicos 03_CHA-M_K_181-P-522-P_clbm_61.7.pdf
- Manuales de instalación, uso y mantenimiento CHA-MK_181P_522P_CLMM_61.7_lRAj8te.pdf