CHA-M/Y 1202÷2003
Aircooled liquid Chillers and Heat Pumps with axial fans, Screw compressors and shell and tube exchanger









The liquid Chillers and Heat Pumps of CHA-M/Y 1202÷2002 ENERGYMAX series, with R134a refrigerant, are designed for large service sector or industrial-type ambients. They are used, in combination with terminal units, for the air conditioning of the rooms or to remove the heat developed during industrial processes.
They are equipped with axial fans, Screw compressors and shell and tube exchanger. The use of large size condensing coils, together with fans with high unit efficiency, as well as the optimization of the hydraulic and cooling circuit and the use of latest generation Screw compressors, combined with a suitable sizing of the user system, allows to obtain high efficiency during operation with remarkably reduced energy consumption.
A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.
Versions
- CHA-M/Y - Cooling only
- CHA-M/Y/WP - Reversible Heat Pump
Power range
- 240-484 kW
- 68,0-138 Ton
Caractéristiques
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Screw compressors with built-in oil separator, suction filter, crankcase heater, oil sight glass, thermal protection, hot gas shut off valves and capacity steps.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coils.
- Shell and tube type evaporator, with two independent circuits on the refrigerant side and one on the water side.
- Electronic expansion valve.
- R134a refrigerant.
- Electrical board includes: main switch with door safety interlock, protection modules, overload protection for compressors and thermocontacts for fans.
- Condensing control included, allows to reach up to 0 °C external air temperature.
- Microprocessor control and regulation system.
Accessoires
Accessoires montés en usine
- RZ Partialisation des compresseurs
- BT Dispositif pour fonctionnement à basse température de l'eau
- HR Désurchauffeur
- HRT/S Récupérateur de chaleur totale en série
- TX Batterie avec ailettes pré-vernies
- FE Résistance antigel évaporateur
- II Inverter sur un compresseur et soft start pour les autres compresseurs
- ID Inverter sur tous les compresseurs
- SS Démarrage progressif
- WM Web Monitoring - Contrôle à distance sans fil (GPRS/EDGE/3G/TCP-IP)
- AD Paroi séparatrice section air
- IS Protocole Modbus RTU, interface sérielle RS485
- CP Contacts secs
Accessoires fournis séparément
- MN Manomètres de haute et basse pression
- CR Panneau de commande à distance
- AM Plots anti-vibrations à ressort
- RP Grilles de protection batteries
- AG Plots anti-vibrations en caoutchouc
- FL Fluxostat
Technical data
1202 | 1302 | 1502 | 1702 | 1902 | 2002 | |||
Refroidissement | Puissance frigorifique (1) | kW | 240 | 276 | 313 | 368 | 423 | 484 |
Puissance absorbée (1) | kW | 85,1 | 100 | 111 | 131 | 152 | 183 | |
EER (1) | 2,82 | 2,76 | 2,82 | 2,81 | 2,78 | 2,64 | ||
Refroidissement (EN14511) | Puissance frigorifique (1) | kW | 239 | 275 | 312 | 366 | 421 | 482 |
Puissance absorbée (1) | kW | 86,1 | 101 | 112 | 133 | 154 | 185 | |
EER (1) | 2,78 | 2,74 | 2,79 | 2,75 | 2,73 | 2,61 | ||
Chauffage | Puissance thermique (2) | kW | 271 | 302 | 348 | 403 | 466 | 541 |
Puissance absorbée (2) | kW | 88,6 | 99,7 | 112 | 130 | 149 | 178 | |
COP (2) | 3,04 | 3,03 | 3,11 | 3,10 | 3,13 | 3,04 | ||
Chauffage (EN14511) | Puissance thermique (2) | kW | 272 | 303 | 350 | 405 | 468 | 544 |
Puissance absorbée (2) | kW | 91,1 | 102 | 116 | 135 | 154 | 184 | |
COP (2) | 2,99 | 2,97 | 3,02 | 3,00 | 3,04 | 2,96 | ||
Compresseur | Quantité | n° | 2 | 2 | 2 | 2 | 2 | 2 |
Circuits frigorifiques | n° | 2 | 2 | 2 | 2 | 2 | 2 | |
Étages de puissance | n° | 6 | 6 | 6 | 6 | 6 | 6 | |
Évaporateur | Débit d'eau | l/s | 11,47 | 13,19 | 14,95 | 17,58 | 20,21 | 23,12 |
Pertes de charge | kPa | 46 | 47 | 53 | 67 | 53 | 60 | |
Raccords hydrauliques | DN | 100 | 100 | 100 | 100 | 100 | 100 | |
Caractéristiques électriques | Alimentation | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
Courant max. de fonctionnement | A | 212 | 250 | 278 | 334 | 363 | 434 | |
Courant max. de crête | A | 277 | 371 | 385 | 444 | 518 | 611 | |
Pression sonore | Version STD (3) | dB(A) | 76 | 76 | 75 | 77 | 77 | 77 |
Poids | Poids de transport | kg | 2475 | 2842 | 3083 | 3262 | 3500 | 3927 |
Poids en fonctionnement | kg | 2640 | 3000 | 3280 | 3450 | 3690 | 4250 |
Dimensions
1202 | 1302 | 1502 | 1702 | 1902 | 2002 | |||
L | STD | mm | 2800 | 2800 | 3900 | 3900 | 3900 | 3900 |
W | STD | mm | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 |
H | STD | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 |
Remarques
- 1 Eau glacée de 12 à 7 °C, température air extérieur 35 °C.
- 2 Eau chauffée de 40 à 45 °C, température de l'air extérieur 7°C b.s./6°C b.h.
- 3 Niveau moyen de pression sonore mesurée en champ libre à 1 m de l'unité comme défini de ISO 3744.
- N.B. (1) Les poids des versions WP sont rapportés dans le cahier technique.
Documents
- Gamme de produits 00_clint_international_product_over_09.2019_w.pdf
- Guides de produits _clint_international_product_guide_09.2019_w.pdf
- Brochures commerciales 04_clint_international_leaflet_energymax_09.2019_w.pdf
- Cahiers techniques 07_CHA-M_Y_1202-2002_clbm_56.7.pdf
- Manuels d'installation, d'utilisation et d’entretien CHA-MY_1202_2002_CLMM_56.7_J1mW6UD.pdf