CHA-M/SZ/K 724-P÷1306-P
Aircooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger








The models of NEXTPOWER range are dedicated to conditioning of medium and wide areas. The intelligent control module optimizes functioning times and supplied power from compressors based on heat load demands in the system.
The range is equipped with R410A refrigerant and features Scroll compressors and plate exchanger.
High reliability is the key plus of NEXTPOWER, thanks to the use of components built in large series and the management of several compressors allowing an increased compressor life span and the reduction of machine stopping risks: a faulty compressor will not compromise the functioning of the unit, that will continue to work with decreased power levels. The optional Air Section Divider allows to service one circuit without stopping the whole unit.
NEXTPOWER obtains high energy yield with high ESEER values and excellent silent
functioning, since the fans adjust their speed to the actual system load, providing benefits
in terms of silent operation, important especially at night.
NEXTPOWER, thanks to the high partialization and the intelligent control module, doesn't require inertial storage tank.
The units feature 460V power supply and 60Hz frequency.
Versionen
- CHA-M/SZ/K - Cooling only
- CHA-M/SZ/K/WP - Reversible Heat Pump
Power range
- 218-512 kW
- 62,0-146 Ton
Merkmale
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coils.
- Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- Electronic expansion valve.
- R410A refrigerant.
- Electrical board includes: main switch with door safety interlock, protection modules, overload protection for compressors and thermocontacts for fans.
- Microprocessor control and regulation system.
Zubehör
Im Werk montiertes Zubehör
- SL Schalldämmung der Einheit
- CT Verflüssigungsregelung bis 0 °C
- BT Ausführung für Betrieb mit niedriger Wassertemperatur
- DS Enthitzer
- RT Vollständige Wärmerückgewinnung
- TX Register mit vorbeschichteten Lamellen
- AD Trennwand Geräteteil Luft
- IS Modbus RTU-Protokoll, serielle Schnittstelle RS485
Lose mitgeliefertes Zubehör
- MN Hoch- und Niederdruckmanometer
- CR Fernbedienung
- RP Schutzgitter Verflüssigerregister
- AG Gummi-Schwingungsdämpfer
Technical data
724-P | 824-P | 1044-P | 1206-P | 1306-P | |||
Kühlung | Kühlleistung (1) | kW | 218 | 292 | 366 | 442 | 512 |
Leistungsaufnahme (1) | kW | 76 | 100 | 121 | 156 | 194 | |
Heizung | Heizleistung (2) | kW | 253 | 336 | 405 | 500 | 593 |
Leistungsaufnahme (2) | kW | 82,2 | 109 | 129 | 166 | 191 | |
Verdichter | Anzahl | n° | 4 | 4 | 4 | 6 | 6 |
Kältekreisläufe | n° | 2 | 2 | 2 | 2 | 2 | |
Leistungsstufen | n° | 4 | 4 | 4 | 6 | 6 | |
Verdampfer | Wassermenge | l/s | 10,42 | 13,95 | 17,49 | 21,12 | 24,46 |
Druckverluste | kPa | 53 | 64 | 62 | 52 | 48 | |
Wasseranschlüsse | DN | 100 | 100 | 100 | 100 | 100 | |
Elektrische Merkmale | Versorgungsspannung | V/Ph/Hz | 460/3/60 | 460/3/60 | 460/3/60 | 460/3/60 | 460/3/60 |
Max. Betriebsstrom | A | 140 | 170 | 217 | 255 | 314 | |
Max. Anlaufstrom | A | 296 | 357 | 445 | 448 | 543 | |
Schalldruck | Version STD (3) | dB(A) | 67 | 68 | 68 | 69 | 70 |
Mit Zubehör SL (3) | dB(A) | 64 | 65 | 65 | 66 | 67 | |
Gewichte | Transportgewicht | kg | 1543 | 1634 | 2192 | 2318 | 2510 |
Betriebsgewicht | kg | 1580 | 1675 | 2240 | 2370 | 2565 |
Dimensions
724-P | 824-P | 1044-P | 1206-P | 1306-P | |||
L | STD | mm | 2800 | 2800 | 3900 | 3900 | 3900 |
W | STD | mm | 2200 | 2200 | 2200 | 2200 | 2200 |
H | STD | mm | 2100 | 2100 | 2100 | 2100 | 2100 |
Aufzeichnungen
- 1 Kaltwasser von 12 bis7 °C, Außenlufttemperatur 35 °C.
- 2 Warmwasser von 40 bis 45 °C, Außenlufttemperatur 7 °C T.K./6 °C F.K.
- 3 Durchschnittlicher Schalldruckpegel im Freifeld im Abstand von 1 m zur Einheit, gemäß ISO 3744.
- N.B. (1) Die Gewichte der Version WP sind in den technischen Unterlagen aufgeführt.
Dokumente
- Produktübersicht 00_clint_international_product_over_09.2019_w.pdf
- Produkthandbücher _clint_international_product_guide_09.2019_w.pdf
- Kommerzielle Broschüre 03_clint_international_leaflet_nextpower_09.2019_w.pdf
- Technischen Unterlagen 10_CHA-M_SZ_K_724-P-1306-P_clbms_41.7.pdf
- Installations-, Bedienungs- und Wartungshandbücher CHA-MK-724P_1306P_CLMM_41.7_Rb935CF.pdf