RTA/K/EC/ECO 182÷804
Double skin packaged Roof Top units with Scroll compressors, EC Inverter Plug-Fans and Economizer
The double skin packaged Roof Top units are the ideal solution for air conditioning of wide surfaces such as shopping malls and restaurants, canteens or for industrial areas. Those units feature Inverter Scroll compressor with R410A refrigerant and EC Inverter Plug-Fans.
Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in Cooling only and Reversible Heat Pump version.
The flat or pocket filters help to keep the air quality at a suitable level.
The ECO units have an high level of modularity and adaptability to every plant-engineering need: these units feature, in addition to the basic sections, an ECONOMIZER automatically controlled both in FREE-COOLING or FREE-HEATING.
The unit can be equipped, as an option, with Thermodynamic Coil-Boost Heat Recovery to achieve better performance and efficiency both in cooling and heating up to 15%.
On request, units can be supplied with R454B refrigerant.
The units are compliant to the ErP Regulation.
Versionen
- RTA/K/EC/ECO - Cooling only with EC Inverter Plug-Fans and Economizer
- RTA/K/EC/WP/ECO - Reversible Heat Pump with EC Inverter Plug-Fans and Economizer
Power range
- 58,0-252 kW
- 17,0-72,0 Ton
Merkmale
- Structure of base perimeter made of steel sheet elements galvanised. Frame made of extruded aluminium alloy profiles connected by 3 way joints. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Condenser and evaporator with copper tube and aluminium finned coil.
- Delivery & intake centrifugal fans coupled to 3-phase motors by V belt and variable pulley.
- High efficiency delivery & intake reverse blade EC INVERTER PLUG-FANS, with electronic speed control to easily adapt to the system characteristics.
- Electrical board includes: door interlocking isolator, fuses, thermal protection relays on compressors, thermocontacts for the fans of the condensing unit and contactors for the fan motors of the air handling unit.
- Microprocessor for the automatic control of the unit.
- R410A refrigerant. On request R454B refrigerant.
Zubehör
Im Werk montiertes Zubehör
- HUR Horizontale Luftansaugung, Luftaustritt nach oben, Inspektionstür rechts
- HUL Horizontale Luftansaugung, Luftaustritt nach oben, Inspektionstür links
- HDR Horizontale Luftansaugung, Luftauslass nach unten, Inspektionstür rechts
- HDL Horizontale Luftansaugung, Luftauslass nach unten, Inspektionstür links
- HLR Horizontale Luftansaugung, Luftauslass links, Inspektionstür rechts
- HRL Horizontale Luftansaugung, Luftauslass rechts, Inspektionstür links
- IM Leistungsschutzschalter
- RE Einstellbare minimale und maximale Spannungsrelais und Phasenregelung
- SL Schalldämmung der Einheit
- SNM Luftaustrittsonde
- THCB Thermodynamische Coil-Boost-Wärmerückgewinnung (nur ECO)
- RFM Absperrventil am Kältekreislauf in der Druckleitung
- RFL Absperrventil am Kältekreislauf in der Flüssigkeitsleitung
- CC Verflüssigungsregelung bis -20 °C
- ECA EC-Inverter-Ventilatoren in dem Verflüssiger Geräteteil
- TXC Verflüssigerregister mit vorbeschichteten Lamellen
- TXE Verdampfungsregister mit vorbeschichteten Lamellen
- FT/M6 Flexiblen Taschenfilter mit Wirkungsgrad ePM10 70% (M6)
- FT/M7 Flexiblen Taschenfilter mit Wirkungsgrad ePM2.5 70% (F7)
- FT/M8 Flexiblen Taschenfilter mit Wirkungsgrad ePM1 70% (F8)
- FT/R6 Starre Taschenfilter mit Wirkungsgrad ePM10 70% (M6)
- FT/R7 Starre Taschenfilter mit Wirkungsgrad ePM1 50% (F7)
- FT/R8 Starre Taschenfilter mit Wirkungsgrad ePM1 70% (F8)
- FT/E Elektrofilter
- AT Regelung nach konstantem Luftstrom
- AT/P Reglung mit konstanter Nutzförderhöhe
- AT/C Steuerung des Luftstroms entsprechend der Last
- WS2 Warmwasserregister mit 3-Wege-Ventil
- EHG Stufen-Elektroheizregister
- CH Enthalpiekontrolle
- SQ Fühler für Luftqualität
- SQO Fühler für Luftqualität (CO2)
- SQV Fühler für Luftqualität (CO2+VOC)
- SSA Aktive Desinfektionssysteme für Luft und Räumen
- PF Differentialdruckwächter für Filterüberwachung
- SB Feuermelder
- SC Rauchmelder
- IS Modbus RTU-Protokoll, serielle Schnittstelle RS485
- IST Protokoll Modbus TCP/IP, Ethernet-Port
- ISBT BACnet IP-Protokoll, Ethernet-Port
- ISB1 BACnet MSTP-Protokoll, serielle Schnittstelle RS485, BTL-zertifiziert.
- ISBT1 BACnet IP-Protokoll, Ethernet-Port, BTL-zertifiziert.
- ISS Protokoll SNMP, Ethernet-Port
- IAV Externe Sollwertverschiebung über 0-10V-Signal
- IAA Externe Sollwertverschiebung über 4-20mA-Signal
- IAS Externe Freigabe für zweiten Sollwert
- IDL Leistungsbegrenzung über Digitaleingang
- CP Potentialfreie Kontakte
- RP Schutzgitter Verflüssigerregister
- MN Hoch- und Niederdruckmanometer
Lose mitgeliefertes Zubehör
- CR Fernbedienung
- CDT Fernbedienung mit Touchscreen-Raumthermostat
- AG Gummi-Schwingungsdämpfer
Technical data
| 182 | 202 | 242 | 262 | 302 | 363 | 393 | 453 | 524 | 604 | 804 | |||
| Kühlung | Kühlleistung (1) | kW | 57,9 | 65,8 | 77,6 | 87,4 | 98,5 | 113 | 129 | 145 | 168 | 198 | 252 |
| Leistungsaufnahme (1, 2) | kW | 21,7 | 24,8 | 28,7 | 30,3 | 35,1 | 43,0 | 46,5 | 49,4 | 61,4 | 70,8 | 97,6 | |
| Kühlung (EN14511) | SEER (3) | 3,65 | 3,68 | 3,80 | 3,82 | 3,90 | 3,84 | 3,71 | 3,81 | 3,88 | 3,76 | 3,78 | |
| Energieeffizienz (3) | % | 143 | 144 | 149 | 150 | 153 | 151 | 145 | 149 | 152 | 147 | 148 | |
| Heizung | Heizleistung (4) | kW | 60,2 | 67,1 | 76,8 | 88,5 | 101 | 115 | 133 | 151 | 173 | 204 | 262 |
| Leistungsaufnahme (4, 2) | kW | 19,5 | 21,1 | 24,6 | 27,2 | 29,9 | 37,9 | 41,0 | 46,7 | 53,2 | 60,4 | 84,1 | |
| Heizung (EN14511) | SCOP (5) | 3,22 | 3,23 | 3,31 | 3,31 | 3,26 | 3,23 | 3,20 | 3,29 | 3,33 | 3,32 | 3,24 | |
| Energieeffizienz (5) | % | 126 | 126 | 129 | 129 | 127 | 126 | 125 | 129 | 130 | 130 | 127 | |
| Geräteteil Luftaufbereitung | Luftmenge | m³/h | 9800 | 12200 | 14900 | 14900 | 17800 | 20200 | 23300 | 23300 | 30200 | 36100 | 45400 |
| Nutzförderhöhe | PA | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | |
| Ventilator | N° | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 4 | 4 | 4 | |
| Filter | Tipo | G4 | G4 | G4 | G4 | G4 | G4 | G4 | G4 | G4 | G4 | G4 | |
| Geräteteil Lufteinlass | Luftmenge | m³/h | 9800 | 12200 | 14900 | 14900 | 17800 | 20200 | 23300 | 23300 | 30200 | 36100 | 45400 |
| Nutzförderhöhe | PA | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
| Ventilator | N° | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 4 | 4 | |
| Geräteteil Verflüssiger | Verdichter | N° | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 | 4 |
| Kältekreisläufe | N° | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | |
| Leistungsstufen | N° | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 | 4 | |
| Warmwasserregister | Heizleistung (6) | kW | 89 | 106 | 130 | 132 | 144 | 180 | 200 | 201 | 257 | 304 | 336 |
| Luftseitige Druckverluste | PA | 30 | 31 | 31 | 31 | 31 | 30 | 36 | 36 | 35 | 35 | 57 | |
| Wassermenge (6) | l/s | 2,16 | 2,60 | 3,18 | 3,22 | 3,53 | 4,39 | 4,88 | 4,92 | 6,28 | 7,41 | 8,20 | |
| Wasserseitige Druckverluste | kPa | 27 | 28 | 27 | 28 | 33 | 28 | 29 | 29 | 30 | 31 | 37 | |
| Wasseranschlüsse | "G | 1"½ | 1"½ | 1"½ | 1"½ | 1"½ | 2" | 2" | 2" | 2" | 2 ½" | 2 ½" | |
| Elektrisches Widerstand | Versorgungsspannung | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
| Heizleistung | kW | 15 | 21 | 27 | 27 | 27 | 41 | 41 | 41 | 41 | 48 | 55 | |
| Max Stromaufnahme | A | 22 | 30 | 39 | 39 | 39 | 59 | 59 | 59 | 59 | 69 | 79 | |
| Stufen | N° | 2 | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 4 | 4 | |
| Elektrische Merkmale | Versorgungsspannung | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
| Max. Betriebsstrom | A | 46 | 53 | 65 | 71 | 83 | 92 | 101 | 119 | 143 | 167 | 205 | |
| Max. Anlaufstrom | A | 157 | 172 | 161 | 186 | 226 | 187 | 215 | 261 | 257 | 309 | 381 | |
| Schalldruck | STD-Version (7) | dB(A) | 68 | 68 | 67 | 67 | 68 | 71 | 72 | 72 | 72 | 72 | 72 |
| Mit Zubehör SL (7) | dB(A) | 65 | 65 | 64 | 64 | 65 | 68 | 69 | 69 | 69 | 69 | 69 | |
| Gewichte | Transportgewicht | kg | 1570 | 1690 | 1810 | 1910 | 1930 | 2160 | 2560 | 2610 | 3130 | 3500 | 4520 |
| Betriebsgewicht | kg | 1550 | 1660 | 1780 | 1880 | 1900 | 2130 | 2520 | 2570 | 3080 | 3450 | 4450 | |
Dimensions
| 182 | 202 | 242 | 262 | 302 | 363 | 393 | 453 | 524 | 604 | 804 | |||
| L | STD | mm | 5250 | 5350 | 5410 | 5410 | 5660 | 6115 | 6640 | 6640 | 6490 | 6840 | 9160 |
| W | STD | mm | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 |
| H | STD | mm | 2125 | 2365 | 2365 | 2365 | 2365 | 2365 | 2365 | 2365 | 2365 | 2505 | 2505 |
Aufzeichnungen
- 1 Lufteintrittstemperatur an Verdampfer 27 °C T.K. / 19 °C F.K.; Außenlufttemperatur 35 °C.
- 2 Gesamtleistungsaufnahme.
- 3 Saisonale Energieeffizienz im Kühlbetrieb gemäß EU-Verordnung 2016/2281.
- 4 Lufteintrittstemperatur an Verflüssiger 20 °C; Außenlufttemperatur 7 °C T.K./6 °C F.K.
- 5 Saisonale Energieeffizienz im Heizbetrieb in durchschnittlichen Wetterbedingungen gemäß EU-Verordnung 2016/2281.
- 6 Lufteintrittstemperatur 20 °C; Wassereintrittstemperatur 70 °C; Wasseraustrittstemperatur 60 °C.
- 7 Durchschnittlicher Schalldruckpegel im Freifeld im Abstand von 1 m zur Einheit, gemäß ISO 3744.
- N.B. (1) Das Gewicht der Versionen WP ist in den technischen Unterlagen aufgeführt.