clint AQUAPLUS.pdf

CWW/K 31÷151

Water cooled liquid Chillers and Heat Pumps with Rotary/Scroll compressor and plate exchangers

_icona_clint_solo_raffreddamento-riscaldamento_2024.psd _icona_clint_compressore_rotary_2024.psd _icona_clint_compressore_scroll_2024.psd _icona_clint_exchanger_plate_2024.psd _icona_clint_refrigerant_R410A_2024.psd _icona_clint_solo_raffreddamento_2024.psd

The CWW/K 15÷151 liquid Chillers and Heat Pumps, with R410A refrigerant, are designed for small and medium domestic or industrial systems which require medium-low power, space-saving units and quiet operation. These units are ideal for indoor installation and, equipped with a self-contained structure, they reduce the overall dimensions to a minimum while making installation and maintenance operations easier.
These units can be combined with Fan Coil units or with intermediate heat exchangers for process cooling applications.
Equipped with prepainted plate structure, Scroll compressor and plate exchangers, these units have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency, even in tank and pump version.
A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.
Cooling only units are not compliant to ErP 2021 Regulations for comfort cooling application. Heat Pump units are compliant to ErP Regulations.

Features

  • Self-supporting prepainted steel frame.
  • Scroll compressor with internal overheat protection and crankcase heater, if needed.
  • Condenser AISI 316 stainless steel braze welded plates type, with pressostatic valve.
  • Evaporator AISI 316 stainless steel braze welded plates type, complete with water differential pressure switch.
  • R410A refrigerant.
  • Water circuit for SP version includes: insulated tank, circulating pump, safety valve, gauge and expansion vessel.
  • Electrical board includes: main switch with door lock device, fuses, compressor and pump remote control switch.
  • Microprocessor control and regulation system.

Factory fitted accessories

  • PV Pressure valve (for cooling only versions)
  • VV Pressure valve and solenoid valve (for WP versions)
  • BT Low water temperature kit
  • PS Single circulating pump
  • GS Single circulating pump gasket for glycol >30%
  • FE Antifreeze heater for evaporator
  • FA Antifreeze heater for tank

Loose accessories

  • CR Remote control panel
  • IS Modbus RTU protocol, RS485 serial interface
  • AG Rubber shock absorbers
31415161718191101131151
CoolingCooling capacity (1)kW9,611,614,317,120,023,027,733,639,749,2
Absorbed power (1)kW2,32,93,44,14,85,56,87,99,311,5
EER (1)4,174,004,214,174,174,184,074,254,274,28
Cooling (EN14511)Cooling capacity (1)kW9,511,514,217,019,822,827,533,339,448,8
Absorbed power (1)kW2,53,23,74,45,26,07,48,710,112,1
EER (1)3,783,583,803,863,793,793,723,833,924,03
HeatingHeating capacity (2)kW12,514,917,520,824,328,433,839,847,059,5
COP (2)4,174,264,073,853,984,064,123,944,024,13
CompressorTypeScrollScrollScrollScrollScrollScrollScrollScrollScrollScroll
Quantity1111111111
EvaporatorWater flowl/s0,460,550,680,820,961,101,321,611,902,35
Pressure dropskPa30454229404748604954
Water connections"G1"1"1"1"1"1"1"1"1"1"
CondenserWater flowl/s0,140,170,210,250,300,340,410,500,580,73
Pressure dropskPa81058101320212222
Water connections"G1"1"1"1"1"1"1"1"1"1"
Electrical characteristicsPower supplyV/Ph/Hz230/1/50230/1/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50400/3+N/50
Max. running currentA1622911141518202329
Max. starting currentA758650717474142142147197
Unit SP versionsWater flowl/s0,460,550,680,820,961,101,321,611,902,35
Pump available static pressurekPa503512813110093187160131155
Tank water volumeL505050505050100100100100
Water connections"G1"1"1"1"1"1"1"1"1"1"
Sound pressureSTD/SP version (3)dB(A)41434344454749495050
WeightsOperating weight (4)kg97100104108110112212221227243
Transport weight (4)kg9699102106108110209218224240
Weight STD versionsTransport weight (4)kg8790939698100190198204218
Heating (EN14511)Heating capacity (2)kW11,913,717,119,722,526,331,837,944,556,4
Absorbed power (2)kW3,73,94,55,66,37,28,910,812,415,2
COP (2)3,253,563,813,503,593,673,563,503,583,71
SCOP (5)4,314,384,343,954,054,054,313,944,184,28
Energy Efficiency (5)%164167166150154154164150159163
Energy Class (6)A++A++A++A+A++A++A++A+A++A++

Dimensions

31415161718191101131151
LSTDmm550550550550550550550550550550
SPmm5505505505505505501100110011001100
WSTD/SPmm550550550550550550550550550550
HSTD/SPmm1200120012001200120012001200120012001200

Notes

  • 1 Chilled water from 12 to 7 °C, water temperature at the condenser from 15 to 35 °C.
  • 2 Heated water from 40 to 45 °C, water temperature at the evaporator from 15 to 10 °C.
  • 3 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
  • 4 Unit without tank and pump.
  • 5 Seasonal energy efficiency of heating at low temperature with average climatic conditions. According to EU Regulation n. 813/2013.
  • 6 Seasonal energy efficiency class of heating at low temperature with average climatic conditions. According to EU Regulation n. 811/2013.
  • N.B. (1) Weights of WP versions are specified on technical brochure.