_clint_logo_midy_line.png

CWW/Y/BH 162-P÷1204-P

WATER COOLED HEAT PUMPS FOR HOT WATER PRODUCTION AT VERY HIGH TEMPERATURE WITH SCROLL COMPRESSORS AND PLATE EXCHANGERS.

SOLO_CALDO.png COMPRESSORE_SCROLL111.png SCAMBIATORE_PIASTRE11.png DOCCIA_CATALOGONE.png _icon_A_CLASS_2018_heating.png R134a_NEW1.png

The units are designed to produce hot water at very high temperature, in compliance with the most stringent directives on energy efficiency and respect for the environment.
In addition to this, their flexibly interacts with all technological plant solutions defined for every type of building, be it residential, commercial or industrial.
These units are ideal for indoor installation and, equipped with a self-contained structure, they can reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier.
Thanks to the high construction standard and the precise regulation system, the units are able to guarantee a very high efficiency both at the nominal operating point and in partial load conditions.
These characteristics are visible on the machine's working range which is among the most extensive on the market with the production of hot water leaving the condenser up to 80 ° C with evaporator water outlet temperatures up to 40 ° C.
The units are compliant to the ErP Regulation.

Versions

  • CWW/Y/BH - Heat Pump

Power range

  • 77.0-550 kW
  • 22.0-156 Ton

Features

  • Self-supporting galvanized steel frame protected with additional protection achieved via polyester powder painting.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 162-P÷602-P models; with two independent circuits on the refrigerant side and one on the water side in 804-P÷1204-P models, complete with water differential pressure switch.
  • Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 162-P÷602-P models; with two independent circuits on the refrigerant side and one on the water side in 804-P÷1204-P models, complete with water differential pressure switch.
  • Electronic expansion valve.
  • Electronic high and low pressure gauges.
  • R134a refrigerant.
  • Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors, interface relay and terminals for external connections.
  • Microprocessor control and regulation system.