DBW-M 030÷200

FAN COIL UNITS WITH CABINET AND CENTRIFUGAL FANS.

_icona_clint_solo_raffreddamento_2024.psd _icona_clint_fan_centrifugo_2024.psd _icona_clint_refrigerant_H2O_2024.psd

The hydronic Fan Coil units with cabinet, DBW 030÷200, feature an exclusive and compact design combined with the highest efficiency and noiseless operation.
Part of an hydronic system equipped with a liquid Chiller, they generate cool air silently and with instantaneous reaction. A filter, easily removable and washable, absorbs and holds suspended dust, allowing constant cleaning cycles and maintaining an adequate air quality, in accordance with hygiene standards, especially in high occupancy locations.
The units, equipped with 3 speed AC motor, allowing user to choose select according to needs, thus assuring a total comfort.

Características

  • Structure made of galvanized steel sheet with electrostatic powder paint complete with polyethylene for thermal and acoustical purpose to prevent insulation fiber taken in the air stream and to attenuate fan noise. Condensate drain pan with drain and polyethylene thermal insulation, equipped with condensate drain on the same side as the water connections.
  • Heat exchanger coil with copper pipes and aluminium fins with manual air vent and drain pan.
  • Centrifugal fan, statically and dynamically balanced to reduce vibration and noise to a minimum, directly coupled with single phase 3-speed electric AC motor (models 030÷120) or to 3-phase motor by belt and pulley, installed on rubber shock absorbers (models 150÷200).
  • Easily removable and washable G2 air filter. Regenerable by washing with water, blowing, or vacuuming.
  • Standard water connections on the left side in front of the unit.
030040050060070090100120150200
RefrigeraciónPotencia frigorífica total (1)kW9,011,714,317,420,125,629,432,845,659,6
Potencia frigorífica sensible (1)kW6,88,610,513,014,918,921,724,833,844,1
Caudal de agua (1)l/h15392001245029843449439150365626783110223
Pérdidas de carga (1)kPa24,641,144,636,250,242,959,435,346,655,6
Caudal de aireMaxm³/h1512187222322800324040324752558075609900
Medm³/h11341404167421002430302435644185------
Minm³/h756936111614001620201623762790------
Presión estática útilVersión STDPA150150150150150150150200200250
Presión sonoraMax (2)dB(A)66676969697072728487
Med (2)dB(A)6365686767687170------
Min (2)dB(A)6264686666677169------
Características eléctricasAlimentaciónV/Ph/Hz230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50400/3/50400/3/50
Potencia absorbida máxkW0,450,530,810,880,961,121,661,761,592,44
Conexiones hidráulicas"GDN25DN25DN25DN25DN25DN25DN25DN25DN40DN50
PesosPeso de transportekg606667699297105117140159
LSTDmm7357357357357357357357359601045
WSTDmm600670770900100012001350160012502050
HSTDmm550550550550550550550550635735

Dimensions

030040050060070090100120150200
LSTDmm7357357357357357357357359601045
WSTDmm600670770900100012001350160012502050
HSTDmm550550550550550550550550635735

Notas

  • 1 Temperatura del aire ambiente 27 °C b.s/19 °C b.h., temperatura agua 7/12 °C.
  • 2 Presión sonora medida a una distancia de 1 m y con tiempo de reverberación de 0,5 s.
  • N.B. (1) Se puede añadir glicol etilénico inhibido al agua.
  • N.B. (2) Presión máxima de funcionamiento 1500 kPa.
  • N.B. (3) Temperatura máxima del agua de entrada 90°C.