_clint_hydroplus.png

CWW-M/SZ/K 181-P÷522-P

Watercooled liquid Chillers and Heat Pumps with Scroll compressors and plate exchangers

SOLO_FREDDO.png caldo_e_freddo1.png COMPRESSORE_SCROLL111.png SCAMBIATORE_PIASTRE11.png _clint_asia_icon_60_Hz_2015.png R410A1.png

The CWW-M/SZ/K 181-P÷522-P HYDROPLUS liquid Chillers and Heat Pumps, with R410A refrigerant, are designed for medium-sized domestic or industrial systems which require medium-high power, space-saving units and quiet operation. This range is ideal for indoor installation and, equipped with a self-contained structure, it reduces the overall dimensions to a minimum while at the same time making installation and maintenance operations easier.
Equipped with prepainted plate structure, Scroll compressors and plate type exchangers, these units have cooling and hydraulic circuits complete with everything necessary for quick installation and high energy efficiency, even in the version with tank and pump.
A wide series of accessories, factory-assembled or supplied separately, such as the desuperheater or the total heat recovery, rounds off the variety of equipment in this product range.
 
The units feature 460V power supply and 60Hz frequency.

Versions

  • CWW-M/SZ/K - Cooling only
  • CWW-M/SZ/K/WP - Reversible Heat Pump

Power range

  • 54,0-175 kW
  • 15,0-50,0 Ton

Caractéristiques

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side.
  • Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side, completed with water differential pressure switch.
  • R410A refrigerant.
  • Electrical board includes: main switch with door safety interlock, protection modules and overload protection for compressors.
  • Microprocessor control and regulation system.

Accessoires montés en usine

  • SL Silencieux unité
  • BT Dispositif pour fonctionnement à basse température de l'eau
  • DS Désurchauffeur
  • RT Récupérateur de chaleur totale
  • IS Protocole Modbus RTU, interface sérielle RS485

Accessoires fournis séparément

  • MN Manomètres de haute et basse pression
  • CR Panneau de commande à distance
  • SPU Réservoir tampon et simple pompe de circulation
  • SPD Réservoir tampon et double pompe de circulation
  • PV2 Vanne pressostatique électronique à 2 voies
  • PV3 Vanne pressostatique électronique à 3 voies
  • AG Plots anti-vibrations en caoutchouc
  • AG1 Rubber shock absorbers for SPU and SPD modules
181-P241-P301-P392-P522-P
RefroidissementPuissance frigorifique (1)kW53,872,993,1136175
Puissance absorbée (1)kW11,316,721,130,838,8
ChauffagePuissance thermique (2)kW66,791,1114167217
Puissance absorbée (2)kW14,421,026,539,248,8
CompresseurQuantité11122
Circuits frigorifiques11111
Étages de puissance11122
ÉvaporateurDébit d'eaul/s2,573,484,456,508,36
Pertes de chargekPa3851455055
Raccords hydrauliquesDN3232656565
CondenseurDébit d'eaul/s3,114,285,467,0710,21
Pertes de chargekPa4457465358
Raccords hydrauliquesDN3232656565
Caractéristiques électriquesAlimentationV/Ph/Hz460/3/60460/3/60460/3/60460/3/60460/3/60
Courant max. de fonctionnementA34425183103
Courant max. de crêteA187226278268330
Unité avec réservoir et pompePression statique utile pompekPa130100120125120
Contenu d'eau réservoirl300300300300300
Raccords hydrauliques"G2 ½"2 ½"2 ½"2 ½"2 ½"
Pression sonoreVersion STD (3)dB(A)5959606062
Avec accessoire SL (3)dB(A)5656575759
PoidsPoids de transport (4)kg348366426569678
Poids en fonctionnement (4)kg355375440580705

Dimensions

181-P241-P301-P392-P522-P
LUNITÉmm12001200120016001600
UNITÉ + SPU/SPDmm23102310231027102710
WUNITÉmm680680680680680
UNITÉ + SPU/SPDmm680680680680680
HUNITÉmm15201520152015201520
UNITÉ + SPU/SPDmm15201520152015201520

Remarques

  • 1 Eau glacée de 12 à 7 °C, température de l'eau dans le condenseur de 30 à 35 °C.
  • 2 Eau chauffée de 40 à 45 °C, température de l'eau dans l'évaporateur de 15 à 10 °C.
  • 3 Niveau moyen de pression sonore mesurée en champ libre à 1 m de l'unité comme défini de ISO 3744.
  • 4 Unité sans réservoir et pompe.
  • N.B. (1) Les poids des versions WP sont rapportés dans le cahier technique.