logo_ECO-V-THERM_2024.png

clint tec_ec_inverter_fans_2025.png

clint tec_R290_refrigeranti_2025.png

CHV/P/HE/WP 152-P÷504-P

High efficiency super silenced air cooled dedicated Heat Pumps for high temperature hot water production (up to 70°C) with EC Inverter axial fans, Scroll compressors and plate exchanger

_icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_scroll_2024.png _icona_clint_fan_assiale_inverter_2024.png _icona_clint_exchanger_plate_2024.png _icona_clint_solution_DHW_2024.png _icona_clint_solution_leaf-electric_2024.png _icona_clint_solution_A_class_heating_2024.png _icona_clint_refrigerant_R290_2024.png

The units are compliant to the ErP Regulation.

Versions

  • CHV/P/HE/WP - High efficiency super silenced reversible Heat Pump

Power range

  • 52,0-166 kW
  • 15,0-47,0 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Evaporator AISI 316 stainless steel braze welded plates type with one (mod. 152-P÷252-P) or two (mod. 304-P÷504-P) independent circuits on the refrigerant side and one on the water side, completed with water differential pressure switch, and antifreeze heater.
  • R290 refrigerant.
  • The production of hot water up to 70 °C is reachable with outside air temperature down to 3 °C. With outside air temperature of -20 °C the reachable production of hot water is up to 55 °C.

Factory fitted accessories

  • RE Adjustable minimum/maximum voltage and phase control relay
  • PFC1 Power factor correction condensers (cosφ 0,95)
  • DSV Double relief safety valve with changeover switch on the high pressure side for each refrigerant circuit
  • BT Low water temperature kit
  • SI Inertial tank
  • PS Single circulating pump
  • PSI Inverter single circulating pump
  • PD Double circulating pump
  • PDI Inverter double circulating pump
  • GS Single circulating pump gasket for glycol >30%
  • GD Double circulating pump gaskets for glycol >30%
  • FO Antifreeze heater for tank and pipes
  • FG Antifreeze heater for single pump and pipes
  • FM Antifreeze heater for double pump and pipes
  • FUM Antifreeze heater for tank, single pump and pipes
  • FDM Antifreeze heater for tank, double pump and pipes
  • FEV Antifreeze heater for fans
  • SS Soft start
  • ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified.
  • ISBT1 BACnet IP protocol, Ethernet port, BTL certified.
  • IEH Gateway with Ethernet port. Possibility of connection via Modbus TCP-IP (IST) or SNMP (ISS) protocols or via Web Server
  • LDS Leak detection sensor R290
  • GP Anti-snow coils protection grids

Loose accessories

  • V3D 3-Way valve for domestic hot water production
  • AG Rubber shock absorbers
  • AM Spring shock absorbers
  • FL Flow switch