clint tec_inverter_screw.png

CHA/Y/EP 1352÷4402

Aircooled 4-Pipe multifunctional units with EC Inverter axial fans, Inverter Screw compressors and shell and tube exchangers

_icona_clint_solo_raffreddamento_2024.png _icona_clint_solo_riscaldamento_2024.png _icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_screw_inverter_2024.png _icona_clint_fan_assiale_inverter_2024.png _icona_clint_exchanger_shell_and_tube_2024.png _icona_clint_solution_4P_2024.png _icona_clint_solution_DHW_2024.png _icona_clint_solution_web_monitoring_2024.png _icona_clint_refrigerant_R134a_2024.png _icona_clint_refrigerant_R513A_2024.png

ENERGYPOWER is the range of high efficiency multifunctional units for 4-Pipe systems.
The units CHA/Y/EP 1352÷4402, with R134a refrigerant, are provided with latest generation of Inverter Screw compressors and EC Inverter axial fans, to reach high EER/COP/TER and SEER/SCOP energy values. Thanks to the advanced control system, the units can simultaneously fulfill the heating, cooling and domestic hot water request of the building. The unit can manage the opposed thermal loads at the same time and reach the highest possible efficiency. ENERGYPOWER units make the traditional layout of the technical plants easier because the production of thermal energy for the several users are joint in one unit only; the result is an advantage in terms of installation, maintenance and management and in the meantime of the comfort needs.
Are available as option the new EC Inverter fans with high available static pressure and efficiency.
The units are compliant to the ErP Regulation.
On request, units can be supplied with R513A refrigerant.

Versions

  • CHA/Y/EP - Multifunctional unit
  • CHA/Y/EP/SSL - Super silenced multifunctional unit

Power range

  • 278-1133 kW
  • 79,0-322 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Screw Inverter compressors with built-in oil separator, suction filter, crankcase heater, oil sight glass and thermal protection.
  • EC Inverter axial fans directly coupled to an Inverter three-phase electric motor with external rotor. They attenuate the sound level of the unit using a continuous regulation of fans rotation speed and allow the cooling operation of the unit up to outside air temperatures of -20 °C.
  • Copper tube and aluminum finned coils.
  • Shell and tube condenser, with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch.
  • Shell and tube evaporator with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch.
  • Cooling circuit shut-off valves on discharge and liquid line.
  • Electronic expansion valve.
  • Electronic high and low pressure gauges.
  • R134a refrigerant. On request R513A refrigerant.
  • Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
  • Microprocessor control and regulation system.

Factory fitted accessories

  • IM Automatic circuit breakers
  • PFC1 Power factor correction condensers (cosφ 0,95)
  • SL Unit silencement
  • DSV Double relief safety valve with changeover switch on the high pressure side for each refrigerant circuit
  • DSVHL Double relief safety valve with changeover switch on the high and on the low pressure side of each refrigerant circuit
  • BT Low water temperature kit
  • ECH EC Inverter fans with high available static pressure
  • TX Coil with pre-coated fins
  • PUC Single circulating pump cooling side
  • PUIC Inverter single circulating pump cooling side
  • PDC Double circulating pump cooling side
  • PDIC Inverter double circulating pump cooling side
  • GS Single circulating pump gasket for glycol >30%
  • GD Double circulating pump gaskets for glycol >30%
  • FI Antifreeze heater for evaporator and condenser
  • FNC Antifreeze heater for pipes cooling side
  • FGC Antifreeze heater for single pump and pipes cooling side
  • FMC Antifreeze heater for double pump and pipes cooling side
  • FNH Antifreeze heater for pipes heating side
  • TS Touch Screen Interface
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • ISBT BACnet IP protocol, Ethernet port
  • ISS SNMP protocol, Ethernet port
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • CP Potential free contacts
  • GDS Leak detector
  • MN High and low pressure gauges

Loose accessories

  • CR Remote control panel
  • RP Coils protection metallic guards
  • AG Rubber shock absorbers
  • AM Spring shock absorbers
  • FL Flow switch