CHA/H/A 351-P÷1221-P
A CLASS energy efficiency aircooled liquid chillers with axial fans, (Inverter) screw compressor and plate exchanger
The CHA/H/A 351-P÷1221-P units, in A CLASS energy efficiency, with HFO-R1234ze refrigerant, are designed to provide an effective solution to highly selective system needs. The latest generation refrigerant HFO-R1234ze, with GWP<1 (Global Warming Potential), is the most environmentally sustainable refrigerant on the market, and meets the strictest international environmental regulations.
Are available as option the new EC Inverter fans with high available static pressure and efficiency for indoor ducted installation.
Units are compliant to the ErP 2021 Regulation for process cooling application; for comfort cooling application they are compliant if provided with EC or ECH accessory (EC Inverter fans).
Versions
- CHA/H/A - Cooling only
- CHA/H/A/MC - Cooling only with MICROCHANNEL condensing coils
- CHA/H/A/SSL - Super silenced cooling only
- CHA/H/A/MC/SSL - Super silenced cooling only with MICROCHANNEL condensing coils
Power range
- 79,0-208 kW
- 22,0-59,0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Screw compressor with built-in oil separator, suction filter, crankcase heater, oil sight glass, thermal protection and stepless capacity steps.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tube and aluminum finned coils or aluminium MICROCHANNEL coils.
- Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side, complete with water differential pressure switch.
- Cooling circuit shut-off valves on discharge and liquid line.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to 0 °C. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation and high and low pressure transducers on cooling circuit.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- SL Unit silencement
- DSV Double relief safety valve with changeover switch on the high pressure side for each refrigerant circuit
- DSVHL Double relief safety valve with changeover switch on the high and on the low pressure side of each refrigerant circuit
- CC Condensing control down to -20 °C
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- RT Total heat recovery
- TX Coil with pre-coated fins
- TXB Coil with epoxy treatment
- SI Inertial tank
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FA Antifreeze heater for tank
- IQ Inverter on one compressor
- SS Soft start
- WM Web Monitoring - Wireless remote monitoring (GPRS/EDGE/4G/TCP-IP)
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISB BACnet MSTP protocol, RS485 serial interface
- ISBT BACnet IP protocol, Ethernet port
- ISS SNMP protocol, Ethernet port
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- CP Potential free contacts
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
- Product overview (IT) _clint_over_prodotti_ITALIA_2022_w_SQ3yMXT.pdf
- Product overview (EN) _clint_product_over_ENG_2022_w_f78t4ut.pdf
- Product overview (FR) _clint_over_prodotti_FRA_2022_w.pdf
- Product overview (ES) _clint_product_over_SPA_2022_w.pdf
- Product guides (IT) Clint_Guida_Prodotti_Italia_05_2022_ITA.pdf
- Product guides (EN) Clint_Product_Guide_Europa_ENG_05_2022_YnaagAG.pdf
- Commercial leaflets (IT) _clint_dpl_refrigeranti_a_basso_gwp_vademecum_tecnico_ITA_07.2022_spZ1Q5j.pdf
- Commercial leaflets (IT) _clint_dpl_refrigeranti_a_basso_gwp_commerciale_ITA_07.2022.pdf
- Commercial leaflets (EN) _clint_dpl_low_gwp_refrigerants_technical_handbook_ENG_07.2022_KGBj1ME.pdf
- Commercial leaflets (EN) _clint_dpl_low_gwp_refrigerants_commercial_ENG_07.2022_w.pdf
- Commercial leaflets (ES) _clint_dpl_refrigerantes_de_bajo_GWP_comercial_SPA_07.2022.pdf
- Commercial leaflets 09_clint_dpl_maxipower_2022_cld_165_w.pdf
- Technical brochures 26_cha_h_a_351P1221P_clb_216_G05JSG7.pdf
- Installation, use and maintenance manuals (IT) IT_CHA_H_A_351_P_1221_P__CLM-216_REV1.pdf
- Installation, use and maintenance manuals (EN) EN_CHA_H_A_351_P_1221_P__CLM-216_REV1.pdf
- Installation, use and maintenance manuals (DE) DE_CHA_H_A_351_P_1221_P__CLM-216_REV1.pdf
- Installation, use and maintenance manuals (FR) FR_CHA_H_A_351_P_1221_P__CLM-216_REV1.pdf
- Installation, use and maintenance manuals (ES) ES_CHA_H_A_351_P_1221_P__CLM-216_REV1.pdf