CHA/IK/A 91÷151
A CLASS energy efficiency aircooled liquid Chillers and Heat Pumps with axial fans, Inverter Scroll compressor and plate exchanger
The liquid Chillers and Heat Pumps of the CHA/IK/A 91÷151 series, with R410A refrigerant, are designed to satisfy the needs of small and medium domestic and service sector environments.
With a peraluman structure corrosion-resistant over time, these units can be combined with Fan Coil units or with intermediate heat exchangers for process cooling applications.
All units feature A CLASS energy efficiency and are equipped with Inverter control on Scroll compressor for a better efficiency at partial loads (SEER/IPLV/SCOP). The Microchannel condensing coil, available on the dedicated version, ensures an even higher efficiency (high EER), having a better heat exchange than traditional coils.
The units are compliant to the ErP Regulation.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- CHA/IK/A - Cooling only
- CHA/IK/A/MC - Cooling only with MICROCHANNEL condensing coil
- CHA/IK/A/WP - Reversible Heat Pump
Power range
- 26,0-48,0 kW
- 7,3-14,0 Ton
Features
- Structure with supporting frame, in peraluman and galvanized sheet. Sound-proofed compressor compartment.
- DC INVERTER Scroll compressor with oil sight glass, internal overheat protection, crankcase heater and soundproofing cover.
- Axial fans with low ventilation and special wing profile, directly coupled to external rotor motors.
- Condenser made of copper tube and aluminum finned coils or aluminium MICROCHANNEL coils.
- Evaporator AISI 316 stainless steel braze welded plates type, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- Electronic expansion valve.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses and pump remote control switch.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to -20 °C in cooling mode. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation and high and low pressure transducers on cooling circuit.
- Functioning in heating mode with outside air temperature down to -15 °C.
- Microprocessor control and regulation system.
- Advanced functions: remote set-point with 0-10V signal, remote set-point with 4-20mA signal, remote signal for second set-point activation, demand limit from digital input, management of hybrid systems, management of domestic hot water production.
Accessories
Factory fitted accessories
- BT Low water temperature kit
- TX Coil with pre-coated fins
- TXB Coil with epoxy treatment
- PS Single circulating pump
- GS Single circulating pump gasket for glycol >30%
Loose accessories
- CR Remote control panel
- IS Modbus RTU protocol, RS485 serial interface
- RP Coils protection metallic guards
- AG Rubber shock absorbers
Dokumentumok
- Product overview (IT) _clint_over_prodotti_ITALIA_2022_w_SQ3yMXT.pdf
- Product overview (EN) _clint_product_over_ENG_2022_w_f78t4ut.pdf
- Product overview (FR) _clint_over_prodotti_FRA_2022_w.pdf
- Product overview (ES) _clint_product_over_SPA_2022_w.pdf
- Product guides (IT) Clint_Guida_Prodotti_Italia_05_2022_ITA.pdf
- Product guides (EN) Clint_Product_Guide_Europa_ENG_05_2022_YnaagAG.pdf
- Commercial leaflets (IT) _clint_dpl_refrigeranti_a_basso_gwp_vademecum_tecnico_ITA_07.2022_spZ1Q5j.pdf
- Commercial leaflets (IT) _clint_dpl_refrigeranti_a_basso_gwp_commerciale_ITA_07.2022.pdf
- Commercial leaflets (EN) _clint_dpl_low_gwp_refrigerants_technical_handbook_ENG_07.2022_KGBj1ME.pdf
- Commercial leaflets (EN) _clint_dpl_low_gwp_refrigerants_commercial_ENG_07.2022_w.pdf
- Commercial leaflets (ES) _clint_dpl_refrigerantes_de_bajo_GWP_comercial_SPA_07.2022.pdf
- Commercial leaflets 05_clint_dpl_aqua_plus_2023_cld_163.pdf
- Technical brochures 08_cha_ik_a_91151_clb_191_uY5kIrf.pdf
- Installation, use and maintenance manuals (IT) IT_CHA_IK_A_91_151__CLM-191_REV4.pdf
- Installation, use and maintenance manuals (IT) IT_CHA_IG_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (IT) IT_CHA_IL_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (EN) EN_CHA_IK_A_91_151__CLM-191_REV4.pdf
- Installation, use and maintenance manuals (EN) EN_CHA_IG_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (EN) EN_CHA_IL_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (DE) DE_CHA_IK_A_91_151__CLM-191_REV4.pdf
- Installation, use and maintenance manuals (DE) DE_CHA_IG_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (DE) DE_CHA_IL_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (FR) FR_CHA_IK_A_91_151__CLM-191_REV4.pdf
- Installation, use and maintenance manuals (FR) FR_CHA_IG_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (FR) FR_CHA_IL_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (ES) ES_CHA_IK_A_91_151__CLM-191_REV4.pdf
- Installation, use and maintenance manuals (ES) ES_CHA_IG_A_91_151__CLM-191.1_REV0.pdf
- Installation, use and maintenance manuals (ES) ES_CHA_IL_A_91_151__CLM-191.1_REV0.pdf