CHA/K 726-P÷36012-P

Aircooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger

_icona_clint_solo_raffreddamento_2024.png _icona_clint_solo_raffreddamento-riscaldamento_2024.png _icona_clint_compressore_scroll_2024.png _icona_clint_fan_assiale_2024.png _icona_clint_exchanger_plate_2024.png _icona_clint_refrigerant_R410A_2024.png _icona_clint_refrigerant_R452B_2024.png _icona_clint_refrigerant_R454B_2024.png

The liquid Chillers and Heat Pumps of the CHA/K 726-P÷36012-P series, with R410A refrigerant, are designed for large-sized service sector or industrial ambients.
The units are characterized by multi-compressor design on double cooling circuit, to reach high energy performances, reduction of current at start-up, elimination of inertial tanks and excellent silent functioning. The use of components built in large series makes them highly reliable and the management of a high number of compressors allows increased life span with reduction of machine stopping risks and easier maintenance operations.
Are available as option the new EC Inverter fans with high available static pressure and efficiency.
Cooling only units are compliant to the ErP 2021 Regulation for process cooling application; for comfort cooling application they are compliant if provided with EC or ECH accessory (EC Inverter fans).
Heat pump models 726-P÷13010-P are compliant to the ErP Regulation; models
15010-P÷36012-P are compliant if provided with EC or ECH accessory (EC Inverter fans).

On request, units can be supplied with R452B or R454B refrigerant.

Versions

  • CHA/K - Cooling only
  • CHA/K/WP - Reversible Heat Pump
  • CHA/K/SSL - Super silenced cooling only
  • CHA/K/WP/SSL - Super silenced reversible Heat Pump

Power range

  • 199-1051 kW
  • 57,0-299 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Axial fans directly coupled to an electric motor with external rotor.
  • Condenser made of copper tubes and aluminium finned coils.
  • Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
  • Cooling circuit shut-off valve on liquid line in 1048-P÷36012-P models.
  • Electronic expansion valve.
  • Electronic high and low pressure gauges.
  • R410A refrigerant. On request R452B or R454B refrigerant.
  • Electrical board includes: main switch with door safety interlock, fuses or magnetothermic switches, thermal protection relays for compressors and thermocontacts for fans.
  • Microprocessor control and regulation system.

Factory fitted accessories

  • PD Double circulating pump
  • MN High and low pressure gauges
  • IDL Demand limit from digital input
  • IAS Remote signal for second set-point activation
  • IAA Remote set-point, 4-20mA signal
  • IAV Remote set-point, 0-10V signal
  • ISS SNMP protocol, Ethernet port
  • ISBT BACnet IP protocol, Ethernet port
  • ISB BACnet MSTP protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • IS Modbus RTU protocol, RS485 serial interface
  • SS Soft start
  • GD Double circulating pump gaskets for glycol >30%
  • GS Single circulating pump gasket for glycol >30%
  • PDI Inverter double circulating pump
  • SL Unit silencement
  • PSI Inverter single circulating pump
  • PS Single circulating pump
  • EW External water connections
  • TX Coil with pre-coated fins
  • RT Total heat recovery
  • DS Desuperheater
  • ECH EC Inverter fans with high available static pressure
  • EC EC Inverter fans
  • BT Low water temperature kit
  • CC Condensing control down to -20 °C
  • CT Condensing control down to 0 °C
  • RFL Cooling circuit shut-off valve on liquid line
  • RFM Cooling circuit shut-off valve on discharge line

Loose accessories

  • CR Remote control panel
  • RP Coils protection metallic guards
  • AG Rubber shock absorbers
  • AM Spring shock absorbers