CHV/P/HE/WP 152-P÷504-P
High efficiency super silenced air cooled dedicated Heat Pumps for high temperature hot water production (up to 70°C) with EC Inverter axial fans, Scroll compressors and plate exchanger
- Fan: EC axial
- Compressor: Scroll
- Refrigerant: R290
- Hőcserélő: Plate
The units are compliant to the ErP Regulation.
Versions
- CHV/P/HE/WP - High efficiency super silenced reversible Heat Pump
Power range
- 50,0-166 kW
- 14,0-47,0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Evaporator AISI 316 stainless steel braze welded plates type with one (mod. 152-P÷252-P) or two (mod. 304-P÷504-P) independent circuits on the refrigerant side and one on the water side, completed with water differential pressure switch and antifreeze heater.
- R290 refrigerant.
- The production of hot water up to 70 °C is reachable with outside air temperature down to 3 °C. With outside air temperature of -20 °C the reachable production of hot water is up to 55 °C.
Accessories
Factory fitted accessories
- RE Adjustable minimum/maximum voltage and phase control relay
- DSV Double relief safety valve with changeover switch of each refrigerant circuit
- BT Low water temperature kit
- SI Inertial tank
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FX Antifreeze heater for evaporator and pipes
- FQ Antifreeze heater on evaporator, tank and pipes
- FZ Antifreeze heater for evaporator, single pump and pipes
- FH Antifreeze heater for evaporator, double pump and pipes
- FU Antifreeze heater for evaporator, tank, single pump and pipes
- FD Antifreeze heater for evaporator, tank, double pump and pipes
- FEV Antifreeze heater for fans
- SS Soft start
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- IEH Gateway with Ethernet port. Possibility of connection via Modbus TCP-IP (IST) or SNMP (ISS) protocols or via Web Server
- LDS Leak detection sensor R290
- GP Anti-snow coils protection grids
- SEV1 Sequencer, 2 units in a network
- SEV2 Sequencer, 3 to 5 units in a network
- SEV3 Sequencer, 6 to 8 units in a network
- FL Flow switch
Loose accessories
- V3D 3-Way valve for domestic hot water production
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
Product overview
Product guides
Commercial leaflets
Technical brochures
Specification items
Installation, use and maintenance manuals 10
- 32__CHV_P_HE_WP_152-P_504-P__CLM 241_Rev2_DE.pdf
- 32__CHV_P_HE_WP_152-P_504-P__CLM 241_Rev2_EN.pdf
- 32__CHV_P_HE_WP_152-P_504-P__CLM 241_Rev2_ES.pdf
- 32__CHV_P_HE_WP_152-P_504-P__CLM 241_Rev2_FR.pdf
- 32__CHV_P_HE_WP_152-P_504-P__CLM 241_Rev2_IT.pdf
- 32__Handbuch_Regler_PROMA__CL_Rev1_DE.pdf
- 32__Manual_del_controlador_PROMA__CL_Rev1_ES.pdf
- 32__Manuale_controllore_PROMA__CL_Rev1_IT.pdf
- 32__Manuel_du_contrôleur_PROMA__CL_Rev1_FR.pdf
- 32__PROMA_Controller_Manual__CL_Rev1_EN.pdf