CHA/H/A 351÷1221
High efficiency air cooled liquid chillers with axial fans, (Inverter) Screw compressor and shell and tube exchanger
The units are compliant to the ErP 2021 Regulation for process cooling application; for comfort cooling application they are compliant if provided with EC or ECH accessory (EC Inverter fans).
Versions
- CHA/H/A - Cooling only
- CHA/H/A/MC - Cooling only with MICROCHANNEL condensing coils
- CHA/H/A/SSL - Super silenced cooling only
- CHA/H/A/MC/SSL - Super silenced cooling only with MICROCHANNEL condensing coils
Power range
- 79,0-211 kW
- 22,0-60,0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Screw compressor with built-in oil separator, suction filter, crankcase heater, oil sight glass, thermal protection and stepless capacity steps.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tube and aluminum finned coils or aluminium MICROCHANNEL coils.
- Shell and tube evaporator with one independent circuit on the refrigerant side and one on the water side.
- Cooling circuit shut-off valves on discharge and liquid line.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to 0 °C. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation and high and low pressure transducers on cooling circuit.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- DSV Double relief safety valve with changeover switch on the high pressure side for each refrigerant circuit
- DSVHL Double relief safety valve with changeover switch on the high and on the low pressure side of each refrigerant circuit
- CC Condensing control down to -20 °C
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- HRT/S Total heat recovery in series
- TX Coil with pre-coated fins
- TXB Coil with epoxy treatment
- EW External water connections
- SP Inertial tank
- PU Single circulating pump
- PUI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- SPU Inertial tank and single circulating pump
- SPUI Inertial tank and Inverter single circulating pump
- SPD Inertial tank and double circulating pump
- SPDI Inertial tank and Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FB Antifreeze heater for evaporator/tank
- IQ Inverter on one compressor
- SS Soft start
- WM Web Monitoring - Wireless remote monitoring (4G)
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISBT BACnet IP protocol, Ethernet port
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- ISS SNMP protocol, Ethernet port
- MTS Master/Slave Network Management
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- CP Potential free contacts
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
- AM Spring shock absorbers
- FL Flow switch
Dokumentumok
- Product overview (IT) clint_overview_ITA_2025_w.pdf
- Product overview (EN) clint_overview_GLOB_2025_w.pdf
- Product overview (EN) clint_overview_ENG_2025_w.pdf
- Product guides (IT) Guida_Prodotti_CLINT_ITALIA_02_2025_v03_w.pdf
- Product guides (EN) Product_Guide_CLINT_EUROPA_02_2025_v03_w.pdf
- Product guides (EN) Product_Guide_CLINT_EXTRA_EUROPA_02_2025_v03_w.pdf
- Commercial leaflets 09_clint_dpl_maxipower_2022_cld_165_w.pdf
- Technical brochures 28_cha_h_a_3511221_clb_217_ztbUNqM.pdf
- Specification items (EN) _Specification_items_CHA_H_A_351_1221.docx
- Specification items (IT) _Voci_di_capitolato_CHA_H_A_351_1221.docx
- Installation, use and maintenance manuals (IT) IT__CHA_H_A_351_1221__CLM_217__2.pdf
- Installation, use and maintenance manuals (IT) Recuperi_di_calore_IT_0_20250619131740.pdf
- Installation, use and maintenance manuals (IT) 01_IT__Antivibranti_in_gomma_AG.pdf
- Installation, use and maintenance manuals (IT) IT__Gestione_Rete_Master_Slave__CL__0_2_Yzk41Ec.pdf
- Installation, use and maintenance manuals (IT) 06_IT__Trattamenti_batterie.pdf
- Installation, use and maintenance manuals (IT) 02_IT__Antivibranti_a_molla__AM.pdf
- Installation, use and maintenance manuals (EN) EN__CHA_H_A_351_1221__CLM_217__2.pdf
- Installation, use and maintenance manuals (EN) Heat_recovery_EN_0_20250619132524.pdf
- Installation, use and maintenance manuals (EN) 01_EN__Rubber_shock_absorbers_AG.pdf
- Installation, use and maintenance manuals (EN) 02_EN__Spring_shock_absorbers__AM.pdf
- Installation, use and maintenance manuals (EN) 06_EN__Coils_treatments.pdf
- Installation, use and maintenance manuals (EN) EN__Master_Slave_Network_Management__CL__0_3.pdf
- Installation, use and maintenance manuals (DE) DE__CHA_H_A_351_1221__CLM_217__2.pdf
- Installation, use and maintenance manuals (FR) FR__CHA_H_A_351_1221__CLM_217__2.pdf
- Installation, use and maintenance manuals (ES) ES__CHA_H_A_351_1221__CLM_217__2.pdf
- Product guides (EN) KTK_Product_Guide_ENG_02_2025.pdf
- Technical brochures 13_jwa_081211_vv_h_a_ktb_217_gdbAqog.pdf
- Installation, use and maintenance manuals (EN) 47__EN____JWA_081_211_VV_H_A__KTM_217__2.pdf
- Installation, use and maintenance manuals (DE) 47__DE____JWA_081_211_VV_H_A__KTM_217__2.pdf