CHA/IK/A 172-P÷574-P
High efficiency air cooled liquid Chillers and Heat Pumps with axial fans, Inverter Scroll compressors and plate exchanger
- Fan: Axial, EC axial
- Compressor: Inverter Scroll
- Refrigerant: R410A, R452B, R454B
- Hőcserélő: Plate
The units are compliant to the ErP Regulation.
On request, units can be supplied with R452B or R454B refrigerant.
Versions
- CHA/IK/A - Cooling only
- CHA/IK/A/MC - Cooling only with MICROCHANNEL condensing coil
- CHA/IK/A/WP - Reversible Heat Pump
- CHA/IK/A/SSL - Super silenced cooling only
- CHA/IK/A/MC/SSL - Super silenced cooling only with MICROCHANNEL condensing coil
- CHA/IK/A/WP/SSL - Super silenced reversible Heat Pump
Power range
- 50,0-179 kW
- 14,0-51,0 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- DC INVERTER Scroll and ON-OFF Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tube and aluminum finned coil or aluminium MICROCHANNEL coil.
- Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 172-P÷372-P models; with two independent circuits on the refrigerant side and one on the water side in 484-P÷574-P models, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to –20 °C in cooling mode. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation, high and low pressure transducers on cooling circuit and an electrical heater on electrical board.
- Functioning in heating mode with outside air temperature down to -15 °C.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- DS Desuperheater
- HRT/P Total heat recovery in parallel
- TX Coil with pre-coated fins
- TXB Coil with epoxy treatment
- PS Single circulating pump
- PSI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- FE Antifreeze heater for evaporator
- FX Antifreeze heater for evaporator and pipes
- FZ Antifreeze heater for evaporator, single pump and pipes
- FH Antifreeze heater for evaporator, double pump and pipes
- FU Antifreeze heater for evaporator, tank, single pump and pipes
- FD Antifreeze heater for evaporator, tank, double pump and pipes
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISBT BACnet IP protocol, Ethernet port
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- ISS SNMP protocol, Ethernet port
- MTS Master/Slave Network Management
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
- AM Spring shock absorbers
Dokumentumok
Product overview
Product guides
Commercial leaflets
Technical brochures
Specification items
Installation, use and maintenance manuals 15
- 07__CHA_IK_A_172-P_574-P__CLM 171_Rev9_DE.pdf
- 07__CHA_IK_A_172-P_574-P__CLM 171_Rev9_EN.pdf
- 07__CHA_IK_A_172-P_574-P__CLM 171_Rev9_ES.pdf
- 07__CHA_IK_A_172-P_574-P__CLM 171_Rev9_FR.pdf
- 07__CHA_IK_A_172-P_574-P__CLM 171_Rev9_IT.pdf
- 08__CHA_IG_A_172-P_574-P__CLM 171.1_Rev1_DE.pdf
- 08__CHA_IG_A_172-P_574-P__CLM 171.1_Rev1_EN.pdf
- 08__CHA_IG_A_172-P_574-P__CLM 171.1_Rev1_ES.pdf
- 08__CHA_IG_A_172-P_574-P__CLM 171.1_Rev1_FR.pdf
- 08__CHA_IG_A_172-P_574-P__CLM 171.1_Rev1_IT.pdf
- 09__CHA_IL_A_172-P_574-P__CLM 171.1_Rev1_DE.pdf
- 09__CHA_IL_A_172-P_574-P__CLM 171.1_Rev1_EN.pdf
- 09__CHA_IL_A_172-P_574-P__CLM 171.1_Rev1_ES.pdf
- 09__CHA_IL_A_172-P_574-P__CLM 171.1_Rev1_FR.pdf
- 09__CHA_IL_A_172-P_574-P__CLM 171.1_Rev1_IT.pdf