CHA/Y/FC 1202-B÷6002-B
Air cooled liquid Chillers Free-Cooling with axial fans, (Inverter) Screw compressors and shell and tube exchanger
The liquid Chillers of the CHA/Y/FC 1202-B÷6002-B series, with R134a refrigerant, offer innovative technology to meet the needs of large systems for both domestic as well as industrial applications requiring the production of cooled water continuously year-round.
During the cold months, in FREE-COOLING operating mode, the liquid returning from the system is cooled directly by forced convection of outdoor air through the condensing coil, thus saving energy by not operating the unit's Screw compressors. A 3-Way valve system is controlled by the electronic microprocessor controller, allowing functioning in CHILLER, FREE-COOLING or MIXED (simultaneously CHILLER and FREE-COOLING) modes.
On request, units can be supplied with R513A refrigerant.
Versions
- CHA/Y/FC - Cooling only
Power range
- 217-1460 kW
- 62,0-415 Ton
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Screw compressors with built-in oil separator, suction filter, crankcase heater, oil sight glass, thermal protection and stepless capacity steps.
- Axial fans directly coupled to an electric motor with external rotor.
- Condenser made of copper tubes and aluminium finned coils combined with FREE-COOLING coils.
- Shell and tube evaporator with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch.
- Cooling circuit shut-off valves on discharge and liquid line.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R134a refrigerant. On request R513A refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
- Condensing Control is included: electronic proportional device that ensures efficient and continuous functioning of the unit with outside air temperature down to –20 °C. It also allows to reduce the sound level especially at night. It consists of a fans speed controller with continuous speed regulation, high and low pressure transducers on cooling circuit and an electrical heater on electrical board.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- DSV Double relief safety valve with changeover switch on the high pressure side for each refrigerant circuit
- DSVHL Double relief safety valve with changeover switch on the high and on the low pressure side of each refrigerant circuit
- BT Low water temperature kit
- EC EC Inverter fans
- ECH EC Inverter fans with high available static pressure
- TX Coil with pre-coated fins
- SP Inertial tank
- PU Single circulating pump
- PUI Inverter single circulating pump
- PD Double circulating pump
- PDI Inverter double circulating pump
- SPU Inertial tank and single circulating pump
- SPUI Inertial tank and Inverter single circulating pump
- SPD Inertial tank and double circulating pump
- SPDI Inertial tank and Inverter double circulating pump
- GS Single circulating pump gasket for glycol >30%
- GD Double circulating pump gaskets for glycol >30%
- II Inverter on one compressor and soft start for other compressors
- ID Inverter on all compressors
- SS Soft start
- WM Web Monitoring - Wireless remote monitoring (4G)
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISBT BACnet IP protocol, Ethernet port
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- ISS SNMP protocol, Ethernet port
- MTS Master/Slave Network Management
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- CP Potential free contacts
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- RP Coils protection metallic guards
- AG Rubber shock absorbers
- AM Spring shock absorbers
- FL Flow switch
Dokumentumok
- Product overview (IT) clint_overview_ITA_2025_w.pdf
- Product overview (EN) clint_overview_GLOB_2025_w.pdf
- Product overview (EN) clint_overview_ENG_2025_w.pdf
- Product guides (IT) Guida_Prodotti_CLINT_ITALIA_02_2025_v03_w.pdf
- Product guides (EN) Product_Guide_CLINT_EUROPA_02_2025_v03_w.pdf
- Product guides (EN) Product_Guide_CLINT_EXTRA_EUROPA_02_2025_v03_w.pdf
- Commercial leaflets 09_clint_dpl_maxipower_2022_cld_165_w.pdf
- Technical brochures 32_cha_y_fc_1202-B6002-B_clb_139_ml4dhJR.pdf
- Specification items (EN) 28_Specification_items_CHA_Y_FC_1202B_6002B.docx
- Specification items (IT) 28_Voci_di_capitolato_CHA_Y_FC_1202B_6002B.docx
- Installation, use and maintenance manuals (IT) IT__CHA_Y_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (IT) IT__CHA_J_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (IT) 01_IT__Antivibranti_in_gomma_AG.pdf
- Installation, use and maintenance manuals (IT) IT__Gestione_Rete_Master_Slave__CL__0_2_Yzk41Ec.pdf
- Installation, use and maintenance manuals (IT) 06_IT__Trattamenti_batterie.pdf
- Installation, use and maintenance manuals (IT) 02_IT__Antivibranti_a_molla__AM.pdf
- Installation, use and maintenance manuals (EN) EN__CHA_Y_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (EN) EN__CHA_J_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (EN) 01_EN__Rubber_shock_absorbers_AG.pdf
- Installation, use and maintenance manuals (EN) 02_EN__Spring_shock_absorbers__AM.pdf
- Installation, use and maintenance manuals (EN) 06_EN__Coils_treatments.pdf
- Installation, use and maintenance manuals (EN) EN__Master_Slave_Network_Management__CL__0_3.pdf
- Installation, use and maintenance manuals (DE) DE__CHA_Y_FC_1202-B_6002-B__CLM_139__4_ue4f9a9.pdf
- Installation, use and maintenance manuals (DE) DE__CHA_J_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (FR) FR__CHA_Y_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (FR) FR__CHA_J_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (ES) ES__CHA_Y_FC_1202-B_6002-B__CLM_139__4.pdf
- Installation, use and maintenance manuals (ES) ES__CHA_J_FC_1202-B_6002-B__CLM_139__4.pdf
- Product guides (EN) KTK_Product_Guide_ENG_02_2025.pdf
- Technical brochures 38_twa-fc_302-1622_vv-y_ktb_139_iK16YZA.pdf
- Installation, use and maintenance manuals (DE) 86__DE____TWA_FC_302_1622_VV_Y__KTM_139__4.pdf
- Installation, use and maintenance manuals (DE) 87__DE____TWA_FC_302_1622_VV_J__KTM_139__4.pdf