clint AQUAPLUS.pdf

CHAXT/K/AF 182-P÷604-P

High efficiency air cooled liquid Chillers and Heat Pumps with axial fans, Scroll compressors and plate exchanger

_icona_clint_solo_raffreddamento_2024.psd _icona_clint_solo_raffreddamento-riscaldamento_2024.psd _icona_clint_compressore_scroll_2024.psd _icona_clint_fan_assiale_2024.psd _icona_clint_exchanger_plate_2024.psd _icona_clint_solution_A_class_cooling_2024.psd _icona_clint_solution_A_class_heating_2024.psd icona_clint_XT.psd _icona_clint_refrigerant_R410A_2024.psd

The liquid Chillers and Heat Pumps of the CHAXT/K/AF 182-P÷604-P series, with R410A refrigerant, are designed for medium-sized service sector or industrial ambients.
Equipped with axial fans, Scroll compressors and plate exchanger, these units can be completed by a hydraulic circuit with tank, with pump, or with tank and pump. A wide range of accessories, factory fitted or supplied separately, complete the outstanding versatility and functionality of the series.

Versions

  • CHAXT/K/AF - Cooling only
  • CHAXT/K/AF/WP - Reversible Heat Pump

Power range

  • 43,0-155 kW
  • 12,0-44,0 Ton

Features

  • Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Axial fans directly coupled to an electric motor with external rotor.
  • Condenser made of copper tubes and aluminium finned coil.
  • Evaporator AISI 316 stainless steel braze welded plates type with one circuit on the refrigerant side and one on the water side in 182-P÷453-P models; with two independent circuits on the refrigerant side and one on the water side in 524-P÷604-P models, complete with water differential pressure switch. On the Heat Pump units it is always installed an antifreeze heater.
  • R410A refrigerant.
  • Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors and thermocontacts for fans.
  • Electrical board with dedicated components sizing and ventilation system for unit operation at high outdoor ambient temperature.
  • Functioning in heating mode with outside air temperature down to -15 °C.
  • Microprocessor control and regulation system.
  • Operating outdoor ambient air temperature up to 52 °C.

Factory fitted accessories

  • IM Automatic circuit breakers
  • RE Adjustable minimum/maximum voltage and phase control relay
  • SL Unit silencement
  • RFM Cooling circuit shut-off valve on discharge line
  • RFL Cooling circuit shut-off valve on liquid line
  • CT Condensing control down to 0 °C
  • CC Condensing control down to -20 °C
  • BT Low water temperature kit
  • EC EC Inverter fans
  • DS Desuperheater
  • RT Total heat recovery
  • TX Coil with pre-coated fins
  • SI Inertial tank
  • PS Single circulating pump
  • PSI Inverter single circulating pump
  • PD Double circulating pump
  • PDI Inverter double circulating pump
  • GS Single circulating pump gasket for glycol >30%
  • GD Double circulating pump gaskets for glycol >30%
  • FE Antifreeze heater for evaporator
  • FA Antifreeze heater for tank
  • SS Soft start
  • IS Modbus RTU protocol, RS485 serial interface
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • MN High and low pressure gauges

Loose accessories

  • CR Remote control panel
  • SQC Sequencer. Option to be compulsorily combined with just one unit in the network.
  • RP Coils protection metallic guards
  • AG Rubber shock absorbers
  • AM Spring shock absorbers