FBW-EH/B 231÷1231

FAN COIL UNITS WITH CABINET AND CENTRIFUGAL FANS.

_icona_clint_solo_raffreddamento-riscaldamento_2024.psd _icona_clint_fan_centrifugo_2024.psd _icona_clint_refrigerant_H2O_2024.psd

The hydronic Fan Coil units with cabinet FBW-EH/B 23÷143, feature an exclusive and compact design combined with the highest efficiency and noiseless operation.
Part of an hydronic system equipped with a liquid Chiller, they generate cool air silently and with instantaneous reaction. A filter, easily removable and washable, absorbs and holds suspended dust, allowing constant cleaning cycles and maintaining an adequate air quality, in accordance with hygiene standards, especially in high occupancy locations.
The units, equipped with 3 speed AC motor, allowing user to choose select according to needs, thus assuring a total comfort.

Caratteristiche

  • Cabinet made of galvanized steel-sheet, with internal 10mm thermal-acoustic insulation.
  • Condensate drain pan provided with natural condensation drain and thermal insulation.
  • Heat exchanger coil made of copper pipes and aluminium fins, water connections provided with anti-torsion system, manual air vent and water drain valves.
  • Fan section provided with centrifugal fan directly coupled to the 3 speed AC motor. User can select High, Medium and Low fan speed according to requirement.
  • Easily removable and washable nylon air filter.
  • Standard water connections on the left side in front of the unit.
23133143153163183110311231
RaffreddamentoResa frigorifera totale (1)kW2,533,314,245,005,898,049,2911,80
Resa frigorifera sensibile (1)kW1,492,102,853,354,045,526,738,30
Portata acqua (1)l/h4405707308601010138016002030
Perdite di carico (1)kPa1429172433342644
RiscaldamentoResa termica (2)kW2,453,174,094,475,697,298,7911,60
Portata acqua (2)l/h210271350383488625754995
Perdite di carico (2)kPa714222840152140
Portata ariaMaxm³/h3405106808501020136017002040
Medm³/h279418558697836111513941673
Minm³/h1702553404255106808501020
Prevalenza utileVersione STDPA5050505050505050
Pressione sonoraMax (3)dB(A)3435373840414345
Med (3)dB(A)2626303134353638
Min (3)dB(A)2422242526273334
Caratteristiche elettricheAlimentazioneV/Ph/Hz230/1/50 - 60230/1/50 - 60230/1/50 - 60230/1/50 - 60230/1/50 - 60230/1/50 - 60230/1/50 - 60230/1/50 - 60
Potenza assorbita maxkW0,0460,0650,0780,0900,1150,1620,1870,227
Attacchi idraulici"G3/4"3/4"3/4"3/4"3/4"3/4"3/4"3/4"
PesiPeso di trasportokg1518212224343842
LSTDmm560560560560560560560560
WSTDmm6758159159951095142515251725
HSTDmm231231231231231231231231

Dimensioni

23133143153163183110311231
LSTDmm560560560560560560560560
WSTDmm6758159159951095142515251725
HSTDmm231231231231231231231231

Note

  • 1 Temperatura aria ambiente 27 °C b.s./19,5 °C b.u., temperatura acqua 7/12 °C.
  • 2 Temperatura aria ambiente 21 °C b.s., temperatura acqua 45/40 °C.
  • 3 Pressione sonora alla distanza di 1 m dall'unità e tempo di riverbero 0,5 s.
  • N.B. (1) L'acqua può essere addizionata con glicole etilenico inibito.
  • N.B. (2) Pressione massima di esercizio 1500 kPa.
  • N.B. (3) Temperatura massima acqua in ingresso 90 °C.