_clint_tech_ec_inverter_fan_2016.png

TCW 22÷122

Water Cassette with 3-Speed or EC Inverter radial fan

SOLO_FREDDO.png caldo_e_freddo1.png CENTRIFUGO11.png icon_EC_radial_fans_14.png H2O.png

This Water Cassette has been designed to be installed in false ceilings, in domestic environments or the services sector including offices, hotels, restaurants, gyms and shops.
Part of an hydronic system equipped with a liquid Chiller, the Water Cassette generates cool air silently and with instantaneous reaction. During the winter, if combined with a boiler or heat pump, it provides warm air, making it possible to meet home or business heating needs. A filter, which absorbs and retains dust in suspension, allows to keep the air quality at a suitable level, and its easy removal enables continuous cleaning cycles to be carried out, which are particularly important in order to guarantee suitable hygiene standards in highly frequented rooms. The series, in addition to having a rich set of accessories to complete the unit, also has an attractive intake grid that integrates perfectly in the surrounding environment and adjustable deflectors to distribute the air in the room in an ideal manner. Water Cassette features auxiliary moisture drain pan already included and are pre-set for master-slave functioning, with RS485 serial interface. Units are available both with 3-Speed and EC Inverter fans. The units equipped with EC Inverter motor are able to modulate the air flow ensuring a perfect adaptability to the load without any temperature fluctuations, achieving superior performance compared to the traditional solutions even from energy consumption point of view.

Versions

  • TCW - Base unit with remote control
  • TCW/EC - Unit with EC Inverter fan and remote control

Power range

  • 2.4-11.0 kW
  • 0.7-3.1 Ton

Features

  • Structure for insulated recess fitting, limited body depth (250/290 mm) and compact dimensions; specially designed for easy installation and maintenance of the hydraulic and electrical connections, accessible starting from the front panel grid.
  • Casing in insulated galvanized sheet; combined air intake/suction grid; automatic adjustment of air diffusion on the four sides; suction in middle with regenerable filter; precut holes for connection to an external air intake and for connection to a branch duct for conditioning an adjoining room.
  • Combined air diffusion/suction grid with air filter and adjustable air diffusion on the 4 sides with suction in middle.
  • Radial fan turbine with direct feed. The motors, mounted on elastic suspension and equipped with internal thermal safety, are 3-Speed.
  • Radial fan turbine with direct feed. EC INVERTER motors, mounted on elastic suspension and equipped with internal thermal safety (32÷122).
  • Lift pump with float and detection at 3 levels (On-Off-Alarm) of condensation for lift in the upper part of the box. Discharge occurs by gravity, outside the appliance (lift height up to 500 mm).
  • Heat exchanger in copper pipes and aluminium fins with air vent on the headers.
  • Regenerable-type air filter, accessible after opening the combined air intake/suction grid.
  • Microprocessor control with timer for on/off programming. Program for automatic operations, cooling, heating and ventilation; night wellness program and dehumidifier.
  • Infrared remote control with wall support.

Loose accessories

  • EH Supplementary electrical heater
  • DRC Wall mounted automatic electronic control panel
  • V2 3-Way on/off valve for 2-Pipe system
  • V4 3-Way on/off valves for 4-Pipe system
223242536373122
Cooling 2-Pipe unitTotal cooling capacity (1)kW2,43,24,14,96,16,910,9
Sensible cooling capacity (1)kW1,72,53,03,54,95,17,9
Water flow (1)l/h413550705843104911871875
Pressure drops (1)kPa10202842283943
Cooling 2-Pipe unit (EC version)Total cooling capacity (1)kW---3,2---4,6---6,810,9
Sensible cooling capacity (1)kW---2,4---3,2---5,07,9
Water flow (1)l/h---550---791---11701875
Pressure drops (1)kPa---20---39---3938
Heating 2-Pipe unitHeating capacity (2)kW4,96,67,89,711,912,718,9
Water flow (2)l/h422568672834102310901624
Pressure drops (2)kPa8172540242632
Heating 2-Pipe unit (EC version)Heating capacity (2)kW---7,1---9,2---13,418,3
Water flow (2)l/h---610---791---11521574
Pressure drops (2)kPa---20---34---3125
Water connections2 tubi (In / Out)"G3/4"3/4"3/4"3/4"3/4"3/4"3/4"
Air flowMaxm³/h380580730810105013002130
Medm³/h2402905206178209601640
Minm³/h2002004504507007001380
Air flow (EC version)Maxm³/h---580---810---13002100
Medm³/h---400---520---8201380
Minm³/h---200---200---360820
Electrical heaterPower supplyV/Ph/Hz230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50
Absorbed powerkW1122334
Electrical characteristicsPower supplyV/Ph/Hz230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50230/1/50
Max absorbed powerkW0,040,060,060,090,110,150,29
Electrical characteristics (EC version)Power supplyV/Ph/Hz---230/1/50---230/1/50---230/1/50230/1/50
Max absorbed powerkW---0,03---0,04---0,090,20
Sound pressureMax (3)dB(A)39424648515355
Med (3)dB(A)33364043444848
Min (3)dB(A)31313434393942
Sound pressure (EC version)Max (3)dB(A)---42---48---5354
Med (3)dB(A)---39---39---4345
Min (3)dB(A)---29---29---3436
WeightsTransport weightkg31313333404055
Operating weightkg28283030363650

Dimensions

223242536373122
LBODYmm580580580580730730830
PANELmm680680680680830830980
WBODYmm580580580580730730830
PANELmm680680680680830830980
HBODYmm250250290290260260290
PANELmm28282828282828

Notes

  • 1 Ambient air temperature 27 °C d.b./19 °C w.b., water temperature 7/12 °C.
  • 2 Ambient air temperature 20 °C d.b., water temperature 70/60 °C.
  • 3 Sound pressure level measured at 1 m from the unit with reverberation time 0,5 s.
  • N.B. (1) Maximum operating pressure 1000 kPa.
  • N.B. (2) Maximum inlet water temperature 80 °C.
  • N.B. (3) Inhibited ethylene glycol can be added to the water.