CWW/K 726-P÷36012-P
Water cooled liquid Chillers and Heat Pumps with Scroll compressors and plate exchangers
- Compressor: Scroll
- Refrigerant: R452B, R454B
- Heat Exchanger: Plate
The CWW/K 726-P÷36012-P series liquid Chillers and Heat Pumps, with R410A refrigerant, are designed for medium and large domestic or industrial systems which require medium-high power, space-saving units and quiet operation. These units are ideal for indoor installation and, equipped with a self contained structure, they reduce the overall dimensions to a minimum while at the same time making installation and maintenance operations easier.
The units are characterized by multi-compressor design on double cooling circuit, to reach high energy performances, reduction of current at start-up, elimination of inertial tanks and excellent silent functioning. The use of components built in large series makes them highly reliable and the management of a high number of compressors allows increased life span with reduction of machine stopping risks and easier maintenance operations.
The units 726-P÷1128-P are compliant to the ErP Regulation; the units 1208-P÷36012-P are not compliant to the ErP Regulation.
On request, units can be supplied with R452B or R454B refrigerant.
Features
- Structure with supporting frame, made of galvanised sheet metal with additional protection provided by polyester powder coating.
- Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
- Condenser AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side.
- Evaporator AISI 316 stainless steel braze welded plates type with two independent circuits on the refrigerant side and one on the water side, complete with water differential pressure switch.
- Cooling circuit shut-off valve on liquid line in 1048-P÷36012-P models.
- Electronic expansion valve.
- Electronic high and low pressure gauges.
- R410A refrigerant. On request R452B or R454B refrigerant.
- Electrical board includes: main switch with door safety interlock, fuses, thermal protection relays for compressors, interface relay and terminals for external connections.
- Microprocessor control and regulation system.
Accessories
Factory fitted accessories
- IM Automatic circuit breakers
- RE Adjustable minimum/maximum voltage and phase control relay
- SL Unit silencement
- RFM Cooling circuit shut-off valve on discharge line
- RFL Cooling circuit shut-off valve on liquid line
- PV2 2-Way electronic pressostatic valve
- PV3 3-Way electronic pressostatic valve
- BT Low water temperature kit
- BTS Device for operation with geothermal probe
- DS Desuperheater
- FI Antifreeze heater for evaporator and condenser
- SS Soft start
- DPH Device for heating only Heat Pump operation
- WM Web Monitoring - Wireless remote monitoring (4G)
- IS Modbus RTU protocol, RS485 serial interface
- IST Modbus TCP/IP protocol, Ethernet port
- ISBT BACnet IP protocol, Ethernet port
- ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
- ISBT1 BACnet IP protocol, Ethernet port, BTL certified
- ISS SNMP protocol, Ethernet port
- MTS Master/Slave Network Management
- IAV Remote set-point, 0-10V signal
- IAA Remote set-point, 4-20mA signal
- IAS Remote signal for second set-point activation
- IDL Demand limit from digital input
- IVV 0-10V signal for the management of the electronic pressostatic valve source side
- MN High and low pressure gauges
Loose accessories
- CR Remote control panel
- AG Rubber shock absorbers
- AM Spring shock absorbers
Technical data
| 726-P | 786-P | 826-P | 906-P | 1048-P | 1128-P | 1208-P | 13010-P | 15010-P | 16812-P | 18012-P | 20010-P | 24012-P | 27012-P | 30012-P | 33012-P | 36012-P | |||
| Cooling | Cooling capacity (1) | kW | 224 | 250 | 274 | 308 | 345 | 383 | 422 | 462 | 509 | 562 | 622 | 684 | 786 | 895 | 1015 | 1129 | 1242 |
| Absorbed power (1) | kW | 52,0 | 57,0 | 63,0 | 70,0 | 78,0 | 86,0 | 95,0 | 104 | 115 | 129 | 144 | 154 | 176 | 204 | 230 | 261 | 287 | |
| EER (1) | 4,31 | 4,39 | 4,35 | 4,40 | 4,42 | 4,45 | 4,44 | 4,44 | 4,43 | 4,36 | 4,32 | 4,44 | 4,47 | 4,39 | 4,41 | 4,33 | 4,33 | ||
| Cooling (EN14511) | Cooling capacity (1) | kW | 224 | 250 | 274 | 308 | 345 | 383 | 422 | 462 | 508 | 561 | 621 | 683 | 785 | 894 | 1014 | 1128 | 1241 |
| EER (1) | 4,09 | 4,17 | 4,12 | 4,18 | 4,21 | 4,27 | 4,25 | 4,22 | 4,22 | 4,15 | 4,12 | 4,27 | 4,30 | 4,20 | 4,24 | 4,14 | 4,12 | ||
| SEER (2) | 5,27 | 5,52 | 5,56 | 5,87 | 5,61 | 5,99 | 6,08 | 6,08 | 6,14 | 5,95 | 5,96 | 5,91 | 6,22 | 6,08 | 6,16 | 6,03 | 6,03 | ||
| Energy Efficiency (2) | % | 203 | 213 | 214 | 227 | 216 | 232 | 235 | 235 | 238 | 230 | 230 | 228 | 241 | 235 | 238 | 233 | 233 | |
| Heating | Heating capacity (3) | kW | 290 | 320 | 349 | 394 | 437 | 484 | 534 | 584 | 640 | 710 | 783 | 852 | 986 | 1113 | 1255 | 1391 | 1531 |
| Absorbed power (3) | kW | 66,0 | 74,0 | 80,0 | 88,0 | 101 | 111 | 119 | 135 | 144 | 164 | 181 | 198 | 224 | 259 | 289 | 321 | 357 | |
| COP (3) | 4,39 | 4,32 | 4,36 | 4,48 | 4,33 | 4,36 | 4,49 | 4,33 | 4,44 | 4,33 | 4,33 | 4,30 | 4,40 | 4,30 | 4,34 | 4,33 | 4,29 | ||
| Heating (EN14511) | Heating capacity (3) | kW | 291 | 321 | 350 | 395 | 438 | 485 | 535 | 585 | 641 | 711 | 784 | 853 | 987 | 1114 | 1256 | 1392 | 1532 |
| COP (3) | 4,22 | 4,16 | 4,19 | 4,30 | 4,16 | 4,22 | 4,33 | 4,16 | 4,28 | 4,16 | 4,17 | 4,18 | 4,27 | 4,15 | 4,20 | 4,17 | 4,12 | ||
| SCOP (4) | 5,23 | 5,36 | 5,49 | 5,77 | 5,71 | 5,78 | 5,78 | 5,74 | 3,95 | 3,83 | |||||||||
| Energy Efficiency (4) | % | 201 | 206 | 212 | 212 | 223 | 220 | 223 | 223 | 222 | 148 | 146 | 211 | 162 | 152 | 155 | 150 | ||
| Compressor | Quantity | N° | 3+3 | 3+3 | 3+3 | 3+3 | 4+4 | 4+4 | 4+4 | 5+5 | 5+5 | 6+6 | 6+6 | 5+5 | 6+6 | 6+6 | 6+6 | 6+6 | 6+6 |
| Refrigerant circuits | N° | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
| Capacity steps | N° | 6 | 6 | 6 | 6 | 8 | 8 | 8 | 8 | 8 | 10 | 10 | 8 | 10 | 10 | 10 | 10 | 10 | |
| Evaporator | Water flow | l/s | 10,68 | 11,92 | 13,06 | 14,68 | 16,44 | 18,26 | 20,11 | 22,02 | 24,26 | 26,79 | 29,64 | 32,60 | 37,46 | 42,66 | 48,38 | 53,81 | 59,19 |
| Pressure drops | kPa | 54 | 51 | 56 | 56 | 60 | 47 | 52 | 60 | 57 | 70 | 59 | 48 | 53 | 66 | 61 | 70 | 79 | |
| Water connections | DN | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 150 | 150 | 150 | 150 | 150 | 150 | |
| Condenser | Water flow | l/s | 13,30 | 14,80 | 16,24 | 18,22 | 20,39 | 22,60 | 24,92 | 27,28 | 30,08 | 33,30 | 36,92 | 40,39 | 46,36 | 52,97 | 60,00 | 66,99 | 73,69 |
| Pressure drops | kPa | 70 | 74 | 81 | 76 | 67 | 59 | 65 | 75 | 76 | 70 | 77 | 63 | 53 | 65 | 61 | 70 | 78 | |
| Water connections | DN | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 150 | 150 | 150 | 150 | 150 | 150 | |
| Electrical characteristics | Power supply | V/Ph/Hz | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 | 400/3/50 |
| Max. running current | A | 143 | 156 | 164 | 179 | 208 | 223 | 239 | 260 | 298 | 335 | 358 | 394 | 473 | 520 | 566 | 635 | 704 | |
| Max. starting current | A | 266 | 288 | 331 | 346 | 340 | 390 | 406 | 392 | 465 | 502 | 525 | 582 | 660 | 732 | 779 | 870 | 939 | |
| Sound pressure | STD version (5) | dB(A) | 68 | 70 | 71 | 71 | 71 | 72 | 72 | 72 | 73 | 73 | 74 | 77 | 78 | 79 | 79 | 80 | 80 |
| With SL accessory (5) | dB(A) | 65 | 66 | 67 | 67 | 67 | 68 | 68 | 68 | 69 | 69 | 69 | 73 | 74 | 75 | 75 | 76 | 76 | |
| SSL version (5) | dB(A) | 61 | 62 | 63 | 63 | 63 | 64 | 64 | 64 | 65 | 65 | 64 | 69 | 70 | 71 | 71 | 72 | 72 | |
Dimensions
| 726-P | 786-P | 826-P | 906-P | 1048-P | 1128-P | 1208-P | 13010-P | 15010-P | 16812-P | 18012-P | 20010-P | 24012-P | 27012-P | 30012-P | 33012-P | 36012-P | |||
| L | STD/SSL | mm | 2500 | 2500 | 2500 | 2500 | 3000 | 3000 | 3000 | 3550 | 3550 | 4000 | 4000 | 4650 | 4650 | 4650 | 4650 | 4650 | 4650 |
| W | STD/SSL | mm | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 800 | 1350 | 1350 | 1350 | 1350 | 1350 | 1350 |
| H | STD/SSL | mm | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 |
Notes
- 1 Chilled water from 12 to 7 °C, water temperature at the condenser from 30 to 35 °C.
- 2 Seasonal energy efficiency of cooling at low temperature. According to EU Regulation n. 2016/2281.
- 3 Heated water from 40 to 45 °C, water temperature at the evaporator from 15 to 10 °C.
- 4 Seasonal energy efficiency of heating at low temperature with average climatic conditions. According to EU Regulation n. 813/2013.
- 5 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
- N.B. (1) Weights of SSL and WP versions are specified on technical brochure.
Documents
Product overview
Product guides
Specification items
Installation, use and maintenance manuals 15
- 89__CWW_K_726-P_36012-P__CLM 142.7_Rev3_DE.pdf
- 89__CWW_K_726-P_36012-P__CLM 142.7_Rev3_EN.pdf
- 89__CWW_K_726-P_36012-P__CLM 142.7_Rev3_ES.pdf
- 89__CWW_K_726-P_36012-P__CLM 142.7_Rev3_FR.pdf
- 89__CWW_K_726-P_36012-P__CLM 142.7_Rev3_IT.pdf
- 90__CWW_G_726-P_36012-P__CLM 142.8_Rev4_DE.pdf
- 90__CWW_G_726-P_36012-P__CLM 142.8_Rev4_EN.pdf
- 90__CWW_G_726-P_36012-P__CLM 142.8_Rev4_ES.pdf
- 90__CWW_G_726-P_36012-P__CLM 142.8_Rev4_FR.pdf
- 90__CWW_G_726-P_36012-P__CLM 142.8_Rev4_IT.pdf
- 91__CWW_L_726-P_36012-P__CLM 142.8_Rev4_DE.pdf
- 91__CWW_L_726-P_36012-P__CLM 142.8_Rev4_EN.pdf
- 91__CWW_L_726-P_36012-P__CLM 142.8_Rev4_ES.pdf
- 91__CWW_L_726-P_36012-P__CLM 142.8_Rev4_FR.pdf
- 91__CWW_L_726-P_36012-P__CLM 142.8_Rev4_IT.pdf