_clint_logo_air_maxi.eps

clint tec_ec_inverter_plug_fans_2025.eps

RTAXT/K/EC 182÷804

Double skin packaged Roof Top units with Scroll compressors and EC Inverter Plug-Fans

_icona_clint_solo_raffreddamento_2024.psd _icona_clint_solo_raffreddamento-riscaldamento_2024.psd _icona_clint_compressore_scroll_2024.psd _icona_clint_fan_plug_EC_inverter_2024.psd _icona_clint_solution_doppio_pannello_2024.psd _icona_clint_solution_MS_2024.psd icona_clint_XT.psd _icona_clint_refrigerant_R410A_2024.psd

The double skin packaged Roof Top units are the ideal solution for air conditioning of wide surfaces such as shopping malls and restaurants, canteens or for industrial areas. Those units feature Inverter Scroll compressor with R410A refrigerant and EC Inverter Plug-Fans.
Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in Cooling only and Reversible Heat Pump version.
The flat or pocket filters help to keep the air quality at a suitable level.

Versions

  • RTAXT/K/EC - Cooling only with EC Inverter Plug-Fans
  • RTAXT/K/EC/MS - Cooling only with EC Inverter Plug-Fans and Mixing Box
  • RTAXT/K/EC/WP - Reversible Heat Pump with EC Inverter Plug-Fans
  • RTAXT/K/EC/WP/MS - Reversible Heat Pump with EC Inverter Plug-Fans and Mixing Box

Power range

  • 50.0-243 kW
  • 14.0-69.0 Ton

Features

  • Structure of base perimeter made of steel sheet elements galvanised. Frame made of extruded aluminium alloy profiles connected by 3 way joints. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser and evaporator with copper tube and aluminium finned coil.
  • EC INVERTER PLUG-FAN delivery fan with high energy efficient reversed blades with external rotor motor and electronic speed adjustment for easy adaptation to plant features.
  • R410A refrigerant.
  • Electrical board includes: door interlocking isolator, fuses, thermal protection relays on compressors, thermocontacts for the fans of the condensing unit and contactors for the fan motors of the air handling unit.
  • Electrical board with dedicated components sizing and ventilation system for unit operation at high outdoor ambient temperature.
  • Microprocessor for the automatic control of the unit.
  • Operating outdoor ambient air temperature up to 52 °C.

Factory fitted accessories

  • HUR Upwards air delivery, inspection door on the right
  • HUL Upwards air delivery, inspection door on the left
  • HDR Downwards air delivery, inspection door on the right
  • HDL Downwards air delivery, inspection door on the left
  • HLR Air delivery on the left, inspection door on the right
  • HRL Air delivery on the right, inspection door on the left
  • IM Automatic circuit breakers
  • RE Adjustable minimum/maximum voltage and phase control relay
  • SL Unit silencement
  • SNM Air delivery sensor
  • RFM Cooling circuit shut-off valve on discharge line
  • RFL Cooling circuit shut-off valve on liquid line
  • CC Condensing control down to -20 °C
  • TXC Condensing coil with pre-coated fins
  • TXE Evaporating coil with pre-coated fins
  • FT/M6 Soft bag filters efficency ePM10 70% (M6)
  • FT/M7 Soft bag filters efficency ePM2.5 70% (F7)
  • FT/M8 Soft bag filters efficency ePM1 70% (F8)
  • FT/R6 Rigid bag filters efficency ePM10 70% (M6)
  • FT/R7 Rigid bag filters efficency ePM1 50% (F7)
  • FT/R8 Rigid bag filters efficency ePM1 70% (F8)
  • FS Anti-sand filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • AT/C Control adjustment of the air flow according to the load
  • EHG Electrical heater with step regulation
  • PF Differential pressure switch filters control
  • SB Fire sensor
  • SC Smoke sensor
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISBT BACnet IP protocol, Ethernet port
  • ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
  • ISBT1 BACnet IP protocol, Ethernet port, BTL certified
  • ISS SNMP protocol, Ethernet port
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • CP Potential free contacts
  • RP Coils protection metallic guards
  • MN High and low pressure gauges
  • SQ Air quality probe
  • SQO Air quality probe (CO2)
  • SQV Air quality probe (CO2+VOC)

Loose accessories

  • CR Remote control panel
  • CDT Touch Screen room thermostat with unit visualization
  • AG Rubber shock absorbers
182202242262304364404484524604804
CoolingCooling capacity (1)kW49,558,567,076,288,5100112126149176243
Absorbed power (1, 2)kW21,424,227,730,638,441,145,052,463,172,990,2
Cooling capacity (3)kW56,567,376,186,2100115130142169198276
Absorbed power (2, 3)kW18,122,826,128,736,238,342,148,852,368,572,6
HeatingHeating capacity (4)kW58,768,775,387,4102117134148174204288
Absorbed power (2, 4)kW15,718,722,025,030,032,735,443,845,156,160,1
Air treatment sectionAir flowm³/h960011900146001460017400198002280022800295003520044300
Available static pressurePA250250250250250250250250250250250
Fan11222222244
FilterTipoG4G4G4G4G4G4G4G4G4G4G4
Condensing sectionCompressor22224444444
Refrigerant circuits11112222222
Capacity steps22224444444
Hot water coilHeating capacity (5)kW85100125125150175200200250300350
Air pressure dropsPA3031313131303636353535
Water flow (5)l/s2,032,392,992,993,584,184,784,785,977,178,36
Water pressure dropskPa4547484849445151535755
Water connections"G1­"½1­"½1"­½1"­½1"­½2"2"2"2"2 ½"2 ½"
Electrical heaterPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Heating capacitykW1521272727414141414855
Max absorbed currentA2230393939595959596979
Steps22222444444
Electrical characteristicsPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. running currentA4754667283101106115145169191
Max. starting currentA158173162187163212225211259311380
Sound pressureSTD/MS versions (6)dB(A)6869686869717272727272
WeightsTransport weight STDkg10301185118012801390152019001950227024803320
STD operating weightkg10101170116012601370150018701920224024403270

Dimensions

182202242262304364404484524604804
LSTDmm34353435359535954725477547754775477547756800
MSmm38853885404540455170522052255225522552257250
WSTDmm22002200220022002200220022002200220022002200
MSmm22002200220022002200220022002200220022002200
HSTDmm21252365236523652365236523652365236525052505
MSmm21252365236523652340234023652365236525052505

Notes

  • 1 Evaporator inlet air temperature 27 °C d.b./19 °C w.b.; ambient air temperature 46 °C.
  • 2 Total power consumption.
  • 3 Evaporator inlet air temperature 27 °C d.b./19 °C w.b.; ambient air temperature 35 °C.
  • 4 Condenser inlet air temperature 20 °C, ambient air temperature 7 °C d.b./6 °C w.b.
  • 5 Inlet air temperature 20 °C, water temperature 70/60 °C.
  • 6 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.
  • N.B. (1) Weights of WP versions are specified on technical brochure.