Double skin packaged Roof Top units with Scroll compressors and EC Inverter Plug-Fans for 100% external air operation

_icona_clint_solo_raffreddamento_2024.psd _icona_clint_compressore_scroll_2024.psd _icona_clint_fan_plug_EC_inverter_2024.psd icon_FA_14.psd _icona_clint_solution_doppio_pannello_2024.psd icona_clint_XT.psd _icona_clint_refrigerant_R410A_2024.psd

The double skin packaged Roof Top units, using R410A refrigerant, from the FRESH AIR series, are ideal for air conditioning large public areas such as buildings, shopping centres, canteens, restaurants, and clinics; or for industrial environments such as processing or food storage facilities.
Units are designed for operation with 100% of external air, to ensure maximum air renewal.
Those units feature Scroll compressors and EC Inverter Plug-Fans. The EC Inverter Plug-Fans with high energy efficiency backward blades are managed by an electronic control adjusting fans' rotational speed to adapt the air flow to the system capacity.
Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in Cooling only and Reversible Heat Pump version.
The flat or pocket filters help to keep the air quality at a suitable level.

Versions

  • RTAXT/K/EC/FA - Cooling only with EC Inverter Plug-Fans

Power range

  • 54.0-197 kW
  • 15.0-56.0 Ton

Features

  • Structure of base perimeter made of steel sheet elements galvanised. Frame made of extruded aluminium alloy profiles connected by 3 way joints. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser and evaporator with copper tube and aluminium finned coil.
  • EC INVERTER PLUG-FAN delivery fan with high energy efficient reversed blades with external rotor motor and electronic speed adjustment for easy adaptation to plant features.
  • R410A refrigerant.
  • Electrical board includes: door interlocking isolator; fuses; thermal protection relays on compressors; thermocontacts for the fans of the condensing unit; contactors for the fan motors of the air handling unit.
  • Electrical board with dedicated components sizing and ventilation system for unit operation at high outdoor ambient temperature.
  • Electronic proportional device to decrease the sound level, with a continuous regulation of the fan speed. This device allows also the cooling functioning of the unit by external temperature till -5°C.
  • Microprocessor for the automatic control of the unit.
  • Operating outdoor ambient air temperature up to 52 °C.

Factory fitted accessories

  • IM Automatic circuit breakers
  • RE Adjustable minimum/maximum voltage and phase control relay
  • SL Unit silencement
  • SNM Air delivery sensor
  • RFM Cooling circuit shut-off valve on discharge line
  • RFL Cooling circuit shut-off valve on liquid line
  • TXC Condensing coil with pre-coated fins
  • TXE Evaporating coil with pre-coated fins
  • FT/M6 Soft bag filters efficency ePM10 70% (M6)
  • FT/M7 Soft bag filters efficency ePM2.5 70% (F7)
  • FT/M8 Soft bag filters efficency ePM1 70% (F8)
  • FT/R6 Rigid bag filters efficency ePM10 70% (M6)
  • FT/R7 Rigid bag filters efficency ePM1 50% (F7)
  • FT/R8 Rigid bag filters efficency ePM1 70% (F8)
  • FS Anti-sand filter
  • AT Constant air flow regulation control
  • AT/P Constant available static pressure regulation control
  • AT/C Control adjustment of the air flow according to the load
  • PF Differential pressure switch filters control
  • IS Modbus RTU protocol, RS485 serial interface
  • IST Modbus TCP/IP protocol, Ethernet port
  • ISBT BACnet IP protocol, Ethernet port
  • ISB1 BACnet MSTP protocol, RS485 serial interface, BTL certified
  • ISBT1 BACnet IP protocol, Ethernet port, BTL certified
  • ISS SNMP protocol, Ethernet port
  • IAV Remote set-point, 0-10V signal
  • IAA Remote set-point, 4-20mA signal
  • IAS Remote signal for second set-point activation
  • IDL Demand limit from digital input
  • CP Potential free contacts
  • RP Coils protection metallic guards
  • MN High and low pressure gauges

Loose accessories

  • CR Remote control panel
  • CDT Touch Screen room thermostat with unit visualization
  • AG Rubber shock absorbers
182202242262304364404484524604
CoolingCooling capacity (1)kW53,864,277,991,1104118132148171197
Absorbed power (1, 2)kW24,627,933,635,342,749,153,863,074,887,6
Cooling capacity (3)kW52,963,977,790,9104117131148170196
Absorbed power (2, 3)kW19,522,126,927,933,638,942,349,959,470,3
Air treatment sectionAir flowm³/h320042005500630075007500800092001080013000
Available static pressurePA250250250250250250250250250250
Fan1111111111
FilterTipoG4G4G4G4G4G4G4G4G4G4
Condensing sectionCompressor2222444444
Refrigerant circuits1111222222
Capacity steps2222444444
Electrical characteristicsPower supplyV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Max. running currentA394555638189102111113142
Max. starting currentA133143151177161183199225208286
Sound pressureSTD version (4)dB(A)62626262656262626262
WeightsTransport weightkg595665795955117011901200140514401640
Operating weightkg580650780940115511701180138514201620

Dimensions

182202242262304364404484524604
LSTDmm2065231525653690369036903690411042104315
WSTDmm2200220022002200220022002200220022002200
HSTDmm2320232023402340234023402340234023402340

Notes

  • 1 Evaporator inlet air temperature 46 °C d.b./29 °C w.b., ambient air temperature 46 °C.
  • 2 Total power consumption.
  • 3 Evaporator inlet air temperature 35 °C d.b./27 °C w.b.; ambient air temperature 35 °C.
  • 4 Sound pressure level measured in free field conditions at 1 m from the unit. According to ISO 3744.