TOP_AIR.png

_clint_tech_ec_inverter_plug_fans_2016.png

RTA-M/K 181÷602

Double Skin packaged Roof Top units with Scroll compressors and radial fans or EC Inverter Plug-Fans

SOLO_FREDDO.png caldo_e_freddo1.png COMPRESSORE_SCROLL111.png CENTRIFUGO11.png icon_EC_inverter_PLUG-FAN.png _clint_icon_double_skin.png R410A1.png

The double skin packaged Roof Top units of the TOP AIR series are the ideal solution for air conditioning of wide surfaces such as shopping malls and restaurants, canteens or for industrial areas. RTA-M/K units feature Scroll compressors with R410A refrigerant and radial fans or EC Inverter Plug-Fans. The EC Inverter Plug-Fans with high energy efficiency backward blades both for intake as well as delivery are managed by an electronic control adjusting fans' rotational speed to adapt the air flow to the system capacity.
Equipped with extruded aluminium alloy sections and 50mm-thick sandwich panelling, these units are available in Cooling only and Reversible Heat Pump version.
The flat or pocket filters help to keep the air quality at a suitable level in order to guarantee appropriate hygiene standards.

Versioni

  • RTA-M/K - Cooling only with radial fans
  • RTA-M/K/WP - Reversible Heat Pump with radial fans
  • RTA-M/K/EC - Cooling only with EC Inverter Plug-Fans
  • RTA-M/K/EC/WP - Reversible Heat Pump with EC Inverter Plug-Fans

Power range

  • 57,0-192 kW
  • 16,0-55,0 Ton

Caratteristiche

  • Structure of base perimeter made of steel sheet elements galvanised. Frame made of extruded aluminium alloy profiles connected by 3 way joints. Assembling of the base to the frame is of dual support and grants the walking on the base panels installation without sticking out screws. 50mm thick sandwich panels made of prepainted steel sheet; water proofing granted by gaskets having shape memory for perfect seal up even after repeated removals. Section connection is effected by means of assembling conic stirrups and water proofing is granted by gaskets.
  • Scroll compressors with oil sight glass, internal overheat protection and crankcase heater.
  • Condenser and evaporator with copper tube and aluminium finned coil.
  • Delivery radial fans coupled to 3-phase motors by V belt and variable pulley.
  • High efficiency delivery reverse blade EC INVERTER PLUG-FANS, with electronic speed control to easily adapt to the system characteristics.
  • R410A refrigerant.
  • Electrical board includes: door interlocking isolator, fuses, thermal protection relays on compressors, thermocontacts for the fans of the condensing unit and contactors for the fan motors of the air handling unit.
  • Microprocessor for the automatic control of the unit.

Accessori montati in fabbrica

  • SL Silenziamento unità
  • CT Controllo condensazione fino a 0 °C
  • TXC Batteria condensante con alette preverniciate
  • TXE Batteria evaporante con alette preverniciate
  • FT/M6 Filtri a tasche morbide efficienza M6
  • FT/M7 Filtri a tasche morbide efficienza F7
  • FT/M8 Filtri a tasche morbide efficienza F8
  • FT/R6 Filtri a tasche rigide efficienza M6
  • FT/R7 Filtri a tasche rigide efficienza F7
  • FT/R8 Filtri a tasche rigide efficienza F8
  • WS2 Batteria ad acqua calda con valvola a 3 vie
  • EHG Batteria riscaldamento a resistenza elettrica a gradini
  • SQ Sonda qualità aria
  • PF Pressostato differenziale controllo filtri
  • IS Protocollo Modbus RTU, interfaccia seriale RS485
  • CP Contatti puliti
  • RP Reti protezione batterie

Accessori forniti separatamente

  • MN Manometri di alta e bassa pressione
  • CR Pannello comandi remoto
  • AG Antivibranti in gomma

Sezioni aggiuntive

  • UM Sezione con predisposizione per umidificatore
181241301392522602
RaffreddamentoPotenza frigorifera (1)kW57,176,296,0126153192
Potenza assorbita (1)(2)kW20,924,328,638,149,558,2
RiscaldamentoPotenza termica (3)kW59,576,596,3128156195
Potenza assorbita (3)(2)kW18,019,924,133,840,550,8
Sezione trattamento ariaPortata ariam³/s2,74,14,96,38,29,7
Prevalenza utilePa250250250250250250
Ventilatore111111
FiltroTipoG4G4G4G4G4G4
Sezione trattamento aria (versione EC)Portata ariam³/s2,74,14,96,38,29,7
Prevalenza utilePa250250250250250250
Ventilatore122244
FiltroTipoG4G4G4G4G4G4
Sezione motocondensanteCompressore111222
Circuiti frigoriferi111111
Gradini di parzializzazione111111
Batteria ad acqua caldaPotenza termica (4)kW85125150200250300
Perdite di carico lato ariaPa303131363535
Portata acqua (4)l/s2,032,993,584,785,977,17
Perdite di carico lato acquakPa454849515357
Attacchi idraulici"G1­"½1"­½1"­½2"2"2 ½"
Resistenza elettricaAlimentazioneV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Potenza termicakW152727414148
Corrente assorbita max.A223939595969
Stadi222444
Caratteristiche elettricheAlimentazioneV/Ph/Hz400/3/50400/3/50400/3/50400/3/50400/3/50400/3/50
Corrente max. funzionamentoA44536887105136
Corrente max. di spuntoA220265329264318397
Caratteristiche elettriche (versione EC)AlimentazioneV/Ph/Hz400 / 3 / 50400 / 3 / 50400 / 3 / 50400 / 3 / 50400 / 3 / 50400 / 3 / 50
Corrente max. funzionamentoA4046618098134
Corrente max. di spuntoA216258322257311395
Pressione sonora (5) (5)dB(A)595959616262
Pressione sonora (versione EC) (5) (5)dB(A)585858606161
PesiPeso di trasportokg101011571310189022162500
Peso in funzionamentokg100211451298187422002484
Pesi (versione EC)Peso di trasportokg96211151258178421602404
Peso in funzionamentokg95411031246176821442388

Dimensioni

181241301392522602
LSTD/ECmm298031903290450051505300
WSTD/ECmm220022002200220022002200
HSTD/ECmm210023402340234023402510

Note

  • 1 Temperatura aria ingresso evaporatore 27 °C b.s./19 °C b.u.; temperatura aria esterna 35 °C.
  • 2 Esclusa la potenza assorbita dai ventilatori della sezione trattamento aria.
  • 3 Temperatura aria ingresso condensatore 20 °C, temperatura aria esterna 7 °C b.s./6 °C b.u.
  • 4 Temperatura aria ingresso 20 °C, temperatura acqua ingresso 70 °C, temperatura acqua uscita 60 °C.
  • 5 Livello medio di pressione sonora in campo libero ad 1 m dall'unità come definito dalla ISO 3744.
  • N.B. (1) I pesi delle versioni WP sono riportati nel quaderno tecnico.